[Coupling characteristics of cellular electroporation and electrodeformation based on dynamic Young's modulus: influence of membrane thickness].
Rattachement africain : cn. Niveau de preuve : code pays fourni par la source.
Le résumé fourni par la source
To investigate the effect of membrane thickness on the coupled electroporation-electrodeformation response of the cell membrane, a coupled model incorporating a dynamic Young's modulus was developed to simulate transmembrane voltage, spatiotemporal pore evolution, and cell deformation at different membrane thicknesses. As membrane thickness increased from 6 to 10 nm, both the transmembrane voltage and pore radius peaked earlier. At 50 ns, pore density at the cell poles increased by 19.78%-67.44%, total electroporated area by 257.48%-859.36%, and the reduction in Young's modulus became more pronounced. Despite increased membrane softening, peak Maxwell stress decreased by 26.15%-63.28% and remained the dominant factor, reducing peak displacement at the cell poles by 12.35%-34.75%. These findings show that membrane thickness modulates the coupled response by jointly affecting electrically induced pore formation, membrane mechanical properties, and Maxwell stress. The model provides a theoretical basis for designing pulse parameters for cells with different membrane structural characteristics.
Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.
Le contrôle bibliographique ouvert
Les institutions déclarées
Une affiliation ne permet pas de déduire la nationalité d’un auteur.