Local Space-Charge Memory and Grounded-Electrode Transient Response in a Needle–Plane Air Gap Under Polarity Reversal
Résumé fourni par la source
Polarity reversal changes not only the instantaneous electric field in a needle–plane air gap but also the subsequent field–particle coupling through the charged-particle distribution established before reversal. For a configuration in which the grounded needle and grounded lower plate share the same return path, it remains unclear to what extent this local history-dependent state is transferred to the complete grounded conductor and its externally measurable current. Here, a two-dimensional axisymmetric electrostatic model (ES) and a drift–diffusion–reaction–Poisson–discharge-fluid model (EDIS) were established for a 50 mm needle–plane air gap. Positive-to-negative (P2N)/negative-to-positive (N2P) reversals and history-retained/history-reset (H/R) controls were used to separate the effects of reversal path and pre-existing charged-particle state. Over the tested 0–2τ reset-hold range, the representative near-tip electron density in H remained approximately 15–16% higher than that in the corresponding R case, whereas the H/R conductor-integrated response of the complete common-ground assembly was indistinguishable at the present numerical resolution. Outer-domain analysis further showed that for the representative 15 kV case in the 300 mm reference domain, the EDIS and ES common-ground integrated responses differed by approximately 3.3%. Experimentally, P2N and N2P reversals were repeated at 5, 10, and 15 kV, yielding 120 events. The main common-ground current pulse increased with voltage magnitude and maximum voltage slew rate, and the median event-level Pearson correlation with signed dV/dt was approximately 0.989. Different capacitance-baseline constructions yielded central residual-integral levels of approximately 18–19%; after multiplicity correction, the 15 kV fixed-window absolute integral was the direction-sensitive terminal metric with the strongest statistical support. Under the investigated conditions—a nominal 0.5 mm tip radius, 50 mm gap, approximately 3 ms reversal time, and weak-discharge regime—the reversal path and particle history primarily reorganize the near-tip charged-particle state, whereas the dominant scale of the common-ground transient remains closely associated with the applied-voltage variation and the capacitive response of the system.
Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.
Contrôle bibliographique ouvert
DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.
- Titre Crossref
- Local Space-Charge Memory and Grounded-Electrode Transient Response in a Needle–Plane Air Gap Under Polarity Reversal
- Date Crossref
- 27/08/2026
- Éditeur
- MDPI AG
- Type
- journal-article
Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude et ne compte pas comme une seconde source scientifique indépendante.
Institutions déclarées
Une affiliation ne permet pas de déduire la nationalité d’un auteur.