Transcatheter Aortic Valve Replacement for Severe Bicuspid Aortic Valve Stenosis
Résumé fourni par la source
BACKGROUND: Comparative outcomes of transcatheter aortic valve replacement (TAVR) in bicuspid aortic valve (BAV) stenosis remain uncertain. OBJECTIVES: The authors synthesized evidence comparing: 1) TAVR outcomes in BAV vs tricuspid aortic valve (TAV) stenosis; and 2) TAVR vs surgical aortic valve replacement (SAVR) among patients with BAV stenosis. METHODS: MEDLINE, Scopus, and Cochrane CENTRAL were searched through January 31, 2026 (CRD420261304542). Random-effects models pooled risk ratios (RRs) with 95% CIs. Exploratory meta-regression assessed study-level modifiers and temporal trends in 1-year mortality. RESULTS: Fifty-two studies were included. In 39 studies comparing TAVR in BAV vs TAV, BAV was associated with higher paravalvular leak (RR: 1.44; 95% CI: 1.18-1.77; P < 0.001), aortic root injury (RR: 1.83; 95% CI: 1.10-3.04; P = 0.020), 30-day stroke (RR: 1.27; 95% CI: 1.02-1.59; P = 0.035), and 30-day mortality (RR: 1.25; 95% CI: 1.00-1.55; P = 0.047), but lower 1-year mortality (RR: 0.84; 95% CI: 0.75-0.94; P = 0.002). The Society of Thoracic Surgeons score-but not BAV anatomy-predicted 1-year mortality (RR: 1.31; 95% CI: 1.08-1.59; P = 0.006). BAV outcomes improved in recent studies (RR per year, 0.93; 95% CI: 0.87-1.00; P = 0.048). In 13 studies comparing TAVR vs SAVR in BAV, TAVR had higher paravalvular leak (RR: 7.08; 95% CI: 2.28-21.98; P < 0.001) and lower major bleeding (RR: 0.27; 95% CI: 0.17-0.44; P < 0.001) but similar 30-day stroke (P = 0.288) and mortality (P = 0.452). CONCLUSIONS: TAVR for BAV stenosis was associated with procedural risk than TAVR for TAV stenosis but lower 1-year mortality. Compared with SAVR, TAVR showed procedural trade-offs without early mortality differences.
Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.
Contrôle bibliographique ouvert
DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.
- Titre Crossref
- Transcatheter Aortic Valve Replacement for Severe Bicuspid Aortic Valve Stenosis
- Date Crossref
- 01/08/2026
- Éditeur
- Elsevier BV
- Type
- journal-article
Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude et ne compte pas comme une seconde source scientifique indépendante.
Institutions déclarées
Une affiliation ne permet pas de déduire la nationalité d’un auteur.