One-Year Outcomes of M-TEER With the PASCAL System in Atrial and Ventricular FMR: Insights From the MiCLASP Postmarket Clinical Follow-Up Study
Résumé fourni par la source
BACKGROUND: Studies on mitral transcatheter edge-to-edge repair for atrial functional mitral regurgitation (AFMR) and ventricular functional mitral regurgitation (VFMR) are limited. METHODS: We report 1-year outcomes of mitral transcatheter edge-to-edge repair for AFMR and VFMR using the PASCAL transcatheter valve repair system in the MiCLASP multicenter European postmarket clinical follow-up study (REGISTRATION: URL: https://www.clinicaltrials.gov ; Unique identifier: NCT04430075). RESULTS: Analysis included 295 patients with functional mitral regurgitation (75.5±9.93 years old, 59.3% male) from the first 600 enrolled in the MiCLASP study, with AFMR in 17.6% (52) and VFMR in 82.4% (243). Patients with AFMR were older (79.7±6.67 versus 74.6±10.30 years), majority female (75.0% versus 33.3%), and had higher rates of hypertension (98.1% versus 82.3%) and atrial fibrillation (82.7% versus 60.1%) than patients with VFMR (all P <0.05). Patients with VFMR had higher NT-proBNP (N-terminal pro-B-type natriuretic peptide) levels (3350.0 [1720.0–6564.0] versus 1562.0 [790.0–2286.0]; P <0.001) and more severe mitral regurgitation (≥3+) at baseline (71.9% versus 46.2%; P <0.001). Procedural success was high (AFMR, 96.2%; VFMR, 97.1%; P =0.661), and patients with AFMR had shorter procedure duration (73.5 versus 85.5 minutes; P =0.044). One-year Kaplan-Meier estimate of freedom from all-cause mortality or heart failure hospitalizations was 79.3% in AFMR and 70.9% in VFMR ( P =0.267). Both AFMR and VFMR groups demonstrated significant mitral regurgitation reduction (mitral regurgitation ≤1+, 93.1% and 81.3%), low mean transmitral gradients (3.5 and 3.1 mm Hg), significant proportional reductions in left ventricular end-diastolic volume (−12.9% and −16.4%) and left atrial volume (−9.6% and −10.9%), high proportions at New York Heart Association class I/II (76.5% and 64.6%), and significant increases in Kansas City Cardiomyopathy Questionnaire Overall Summary score (+18.0 and +11.6 points), respectively (all P <0.05 from baseline). CONCLUSIONS: One-year MiCLASP results support the safety of mitral transcatheter edge-to-edge repair with the PASCAL system in both AFMR and VFMR, with comparable echocardiographic, functional, and quality-of-life changes, despite baseline differences in clinical presentation.
Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.
Contrôle bibliographique ouvert
DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.
- Titre Crossref
- One-Year Outcomes of M-TEER With the PASCAL System in Atrial and Ventricular FMR: Insights From the MiCLASP Postmarket Clinical Follow-Up Study
- Date Crossref
- 25/08/2026
- Éditeur
- Ovid Technologies (Wolters Kluwer Health)
- Type
- journal-article
Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude et ne compte pas comme une seconde source scientifique indépendante.
Institutions déclarées
Une affiliation ne permet pas de déduire la nationalité d’un auteur.