Implementation science-guided rollout of a standalone radiology clinical decision support system in a tertiary emergency department: findings from a pragmatic controlled before-after study

0Citations signalées, ce qui n’est pas une note de qualité
5Institutions déclarées
2Pays d’affiliation déclarés

Rattachement africain : ie, sg. Niveau de preuve : code pays fourni par la source.

Le résumé fourni par la source

Abstract Background Radiological clinical decision support systems (CDSS) promote value-based healthcare and guide appropriate imaging; however, acceptance and uptake remain inconsistent. Suboptimal implementation can limit the effectiveness of CDSS, widening the research-practice gap. This study examined whether applying implementation science principles for standalone CDSS implementation influenced imaging appropriateness in the emergency department (ED). Methods A pragmatic controlled before-and-after study was conducted. A purposive sample of junior ED physicians was recruited from the largest acute tertiary hospital in Singapore. Implementation science principles from a process model were incorporated in the implementation of the standalone CDSS. Appropriateness rates of X-ray cervical and lumbar spine were examined before and after “Do nothing” and availability of CDSS, respectively with reference to institutional imaging referral guidelines. Radiologically significant positive rates of imaging performed were also explored. Wilcoxon signed-rank tests, Mann-Whitney U tests and multilevel logistic regression models were performed. Results A total of 17 and 23 ED physicians participated in the control and intervention groups, respectively, yielding 593 and 755 imaging procedures for each group. Among physicians in the intervention group, CDSS adoption was 47.8% ( n = 11/23). There were no statistically significant within-group and between-group changes in appropriateness rates. Patient age was strongly associated with appropriateness rate with each additional year of age increasing the appropriateness rate by 8% (OR = 1.08, 95% CI: 1.07–1.09, p < 0.001). Multilevel logistic regression revealed a strong association between appropriateness of imaging and positive radiological findings. Patients with appropriate imaging had higher odds of positive findings compared to inappropriate imaging patients (OR = 21.55, 95% CI: 2.88–161.3, p < 0.05), although the estimate was imprecise due to sparse data. Conclusions Availability of CDSS in the ED did not significantly improve appropriateness rates of cervical and lumbar spine X-rays, suggesting limited practice change from implementing standalone CDSS. There were underlying issues, weaknesses, and gaps in the implementation strategies that constrained the potential of CDSS and warranted attention to optimise its effect on appropriate imaging. Clinical trial number Not applicable.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Le contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Implementation science-guided rollout of a standalone radiology clinical decision support system in a tertiary emergency department: findings from a pragmatic controlled before-after study
Date Crossref
21/08/2026
Éditeur
Springer Science and Business Media LLC
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.

Les institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Les sujets associés

Radiology practices and educationArtificial Intelligence in Healthcare and EducationClinical Reasoning and Diagnostic Skills

BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.