Loop-Mediated Isothermal Amplification (LAMP) Assessment for Malaria Diagnosis in Equatorial Guinea

0Citations signalées — pas une note de qualité
7Institutions déclarées
4Pays d’affiliation déclarés

Résumé fourni par la source

Malaria diagnosis in Equatorial Guinea (EG) is based on conventional microscopy, sometimes combined with rapid diagnostic tests (RDTs). However, some laboratories, such as the Baney Research Laboratory (BRL) have implemented molecular technology for the diagnosis of infectious diseases. This study aimed to evaluate, for the first time in EG, a LAMP method for malaria diagnosis, comparing its performance with conventional microscopy performed in EG and with LAMP and PCR diagnostic methods performed at the National Centre of Tropical Medicine (NCTM), Spain. A total of 178 blood samples (including P. falciparum samples and malaria-negative controls) were evaluated using Dual-LAMP-Pspp and Nested-PCR-Pf in Equatorial Guinea. Dual-LAMP-Pspp performed at the BRL showed sensitivity and specificity values of 97.28% and 100%, respectively, for malaria diagnosis, with no differences between colorimetric and fluorescence-based result readings. Meanwhile, Nested-PCR-Pf showed a sensitivity of 87.07% and a specificity of 100%. Comparison of parasite densities determined by Dual-LAMP-Pspp and conventional microscopy showed a significant moderate negative correlation (correlation coefficient = −0.584). The comparison of Dual-LAMP-Pspp results between BRL and NCTM showed a kappa coefficient of 0.93, whereas the kappa coefficient of the Nested-PCR-Pf assay was 0.70. These findings indicate that Dual-LAMP-Pspp and Nested-PCR-Pf are suitable methods for malaria diagnosis in EG. However, the Dual-LAMP-Pspp assay was easy to perform and interpret and provided results in a shorter time than Nested-PCR-Pf.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Loop-Mediated Isothermal Amplification (LAMP) Assessment for Malaria Diagnosis in Equatorial Guinea
Date Crossref
20/08/2026
Éditeur
MDPI AG
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude et ne compte pas comme une seconde source scientifique indépendante.

Institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Sujets associés

Malaria Research and ControlBiosensors and Analytical DetectionParasitic Diseases Research and Treatment

BNTIC News n’est pas le producteur de ces données. Recherche à la demande dans Crossref et Europe PMC, sans clé ; OpenAlex reste optionnel. Aucun service payant requis, aucune réponse conservée. Sources et limites.