Aller au contenu principal
Accès ouvert déclaré 2026 review

Comparative Efficacy and Safety of Pulsed Field Ablation and Conventional Thermal Ablation for Atrial Fibrillation: A GRADE assessed Systematic Review and Meta analysis of Randomized Controlled Trials

0Citations signalées, ce qui n’est pas une note de qualité
12Institutions déclarées
3Pays d’affiliation déclarés

Rattachement africain : pk, us, Rwanda. Niveau de preuve : code pays fourni par la source.

Le résumé fourni par la source

Background Pulsed field ablation (PFA) is a nonthermal alternative to conventional thermal ablation (TA) for atrial fibrillation (AF), but comparative certainty across outcomes remains variable. Methods We systematically reviewed randomized controlled trials comparing PFA with radiofrequency or cryoballoon ablation. Primary analyses were restricted to paroxysmal AF; exploratory analyses incorporated trials enrolling persistent or mixed AF populations. Random-effects meta-analyses evaluated efficacy, safety, quality of life, and procedural outcomes, with certainty assessed using GRADE. Results Four RCTs (1,393 participants) contributed to the primary analyses. PFA did not differ from TA in atrial arrhythmia recurrence (RR 1.00, 95% CI 0.67–1.49) or single-procedure success (RR 1.04, 95% CI 0.92–1.17). Serious adverse events were also similar (RR 0.94, 95% CI 0.71–1.25). PFA significantly reduced skin-to-skin procedural time (MD −17.04 minutes, 95% CI −20.84 to −13.23). Exploratory analyses incorporating two additional RCTs generally supported these findings, including similar recurrence (RR 0.95, 95% CI 0.78–1.16) and single-procedure success (RR 1.06, 95% CI 0.99–1.13). Certainty ranged from moderate to very low across outcomes, with risk of bias, imprecision, and inconsistency contributing to downgrading. Conclusion PFA provides similar rhythm efficacy and overall safety to contemporary TA while reducing selected procedural times. However, confidence in individual estimates varies, particularly for rare complications and exploratory procedural outcomes. Further randomized evidence with longer follow-up is needed.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Le contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Comparative Efficacy and Safety of Pulsed Field Ablation and Conventional Thermal Ablation for Atrial Fibrillation: A GRADE assessed Systematic Review and Meta analysis of Randomized Controlled Trials
Date Crossref
20/08/2026
Éditeur
F1000 Research Ltd
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.

Les institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Les sujets associés

Atrial Fibrillation Management and OutcomesCardiac Arrhythmias and TreatmentsMicrobial Inactivation Methods

BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.