Aller au contenu principal
Accès ouvert déclaré 2026 article

First-in-human use of SmartGUIDETM steerable 0.014’’ microguidewire for the treatment of intracranial aneurysms: a prospective single-center case series

0Citations signalées — pas une note de qualité
3Institutions déclarées
2Pays d’affiliation déclarés

Résumé fourni par la source

Abstract Purpose To report the first-in-human, prospective clinical evaluation of a steerable 0.014″ microguidewire SmartGUIDE™ (Artiria Medical, Switzerland) for endovascular treatment of intracranial aneurysms, assessing technical feasibility, safety, and operator-reported usability. Methods Adult patients undergoing elective treatment of unruptured intracranial aneurysms were prospectively enrolled between August 2023 and July 2024 at a single center. All procedures were performed by a senior neurointerventionalist. The primary endpoint was the device technical success, defined as successful SmartGUIDE™ navigation to a predefined anatomical target. Successful microcatheterization over the wire was a clinically meaningful secondary endpoint, together with safety, device-related adverse events, navigation time, and operator-reported usability (5-point Likert scale). Patient-specific Flow Twin ® vascular replicas were used for pre-therapeutic training to refine strategy and mitigate risks inherent to first-in-human use. Clinical and imaging follow-up was performed at 1 year. Results Five patients were included. SmartGUIDE™ successfully reached the predefined target in all procedures (5/5). Microcatheterization was achieved in four cases (4/5). Median SmartGUIDE navigation time was 7 min (IQR 4–10). No wire-related complications or device malfunctions were observed. Operators reported high device usability, with median Likert scores of 4–5/5 across all parameters. At 1-year follow-up, all aneurysms demonstrated complete and stable occlusion without neurological morbidity. Conclusion This first-in-human prospective series supports the feasibility and safety of the SmartGUIDE™ steerable 0.014″ microguidewire for the treatment of intracranial aneurysms. The study reports reliable navigation to the target without device-related malfunction or complication, favorable operator-reported usability, and highlights the value of incorporating patient-specific flow-models for pre-procedural training. Comparative studies are required to establish efficiency advantage over conventional microguidewires.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
First-in-human use of SmartGUIDETM steerable 0.014’’ microguidewire for the treatment of intracranial aneurysms: a prospective single-center case series
Date Crossref
18/08/2026
Éditeur
Springer Science and Business Media LLC
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude et ne compte pas comme une seconde source scientifique indépendante.

Institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Sujets associés

Intracranial Aneurysms: Treatment and ComplicationsVascular Malformations Diagnosis and TreatmentAortic aneurysm repair treatments

BNTIC News n’est pas le producteur de ces données. Recherche à la demande dans Crossref et Europe PMC, sans clé ; OpenAlex reste optionnel. Aucun service payant requis, aucune réponse conservée. Sources et limites.