A standardized measurement-based approach to estimate modelled relative biological effectiveness for auditing carbon ion beams
Rattachement africain : us, it. Niveau de preuve : code pays fourni par la source.
Le résumé fourni par la source
Background and purpose: Differences in dose delivered during carbon radiotherapy are due largely to variations in relative biological effectiveness (RBE), which can be calculated by several models. While RBE can theoretically be calculated using Microdosimetric Kinetic Model (MKM) and measured microdosimetric quantities, clinical implementation relies on lookup tables. There exist no means of measuring RBE by MKM or other common models, including Repair Misrepair Fixation (RMF) and Local Effect Model-I (LEM). This study investigated estimating RBE using a single microdosimetric measurement for each model, allowing measurement-based validation and inter-model comparison. Materials and methods: for two test beams. The fits were applied to microdosimetric data from the remaining simulated beams and experimental measurements to validate resulting RBE predictions against full Monte Carlo-calculated RBE. Results: Modelled RBE calculated using simulated input parameters versus estimated with the measurement-based fit were compared and found to be within ±10% accuracy in 96% (MKM), 100% (LEM), and 98% (RMF) of points. Average estimation uncertainty was 2.6% (MKM), 1.7% (LEM), and 4.3% (RMF). Conclusions: While modelled RBE has extensive associated uncertainty, this study demonstrated that it could be estimated with reasonable accuracy using a standardized measurement-based framework. Results suggested that microdosimetry can be used as a quality assurance tool to characterize carbon fields and verify correct implementation of RBE models.
Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.
Le contrôle bibliographique ouvert
DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.
- Titre Crossref
- A standardized measurement-based approach to estimate modelled relative biological effectiveness for auditing carbon ion beams
- Date Crossref
- 01/09/2026
- Éditeur
- Elsevier BV
- Type
- journal-article
Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.
Les institutions déclarées
Une affiliation ne permet pas de déduire la nationalité d’un auteur.