Mixing a proppant-laden base fluid with high-pressure CO2 can reduce its effective sand volume fraction, thereby impairing proppant placement and fracture conductivity. This study performs a numerical structural screening of the helical guide groove in a centrifugal–filtration sand concentrator intended for the pre-foaming base-fluid line upstream of the foam generator and operating against a 105 MPa outlet backpressure. The full-scale base geometry—an inner diameter of 500 mm, a concentration-zone length of 3500 mm, and 18 slotted-screen openings—was retained, while groove depth (10–40 mm), groove width (110–150 mm), and pitch (300–700 mm) were varied sequentially in 14 factor-level evaluations (12 unique geometries). Steady-state calculations were conducted in ANSYS Fluent 2022 R1 using an Eulerian–Eulerian two-fluid framework, the RNG k–ε turbulence closure, a constant apparent liquid viscosity of 0.040 Pa·s, and a compiled UDF-based phase-selective screen condition. CO2 was not included as a separate phase. Within the investigated ranges, increasing groove depth and width increased the sand volume fraction at the concentrated-fluid outlet, whereas pitch produced a pronounced inverted-U-shaped response. The best tested geometry had a pitch of 500 mm, a width of 150 mm, and a depth of 40 mm, yielding an outlet sand volume fraction of 54.05%. This value is 3.80 percentage points higher than the lowest-performing tested configuration (50.25%), corresponding to a relative increase of 7.56%; it is also 14.05 percentage points above the inlet value of 40.00% and 4.05 percentage points above the engineering target of 50.00%. The results provide comparative numerical evidence for groove-parameter selection; independent experimental validation remains required before field application.
Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.
Contrôle bibliographique ouvert
DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.
- Titre Crossref
- Numerical Structural Screening of a High-Pressure Sand Concentrator for Pre-Foaming Base Fluid in CO2-Foam Fracturing
- Date Crossref
- 15/08/2026
- Éditeur
- MDPI AG
- Type
- journal-article
Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude et ne compte pas comme une seconde source scientifique indépendante.
Institutions déclarées
Une affiliation ne permet pas de déduire la nationalité d’un auteur.