Diagnostic accuracy of point-of-care urine tenofovir test, and associations between metrics of tenofovir use and treatment outcomes in a community ART programme
Résumé fourni par la source
Abstract Background Urine tenofovir (uTFV) and dried blood spot (DBS) tenofovir diphosphate (TFV-DP) concentrations respectively estimate short- and medium-term adherence to tenofovir disoproxil fumarate (TDF)-based antiretroviral therapy (ART). We evaluated the accuracy of a point-of-care uTFV assay, and associations between uTFV/TFV-DP, and viral load (VL) and retention outcomes within a South African community ART programme. Methods We measured uTFV and DBS TFV-DP concentrations using liquid chromatography-tandem mass spectrometry (LC-MS/MS). We calculated sensitivity and specificity of the point-of-care uTFV assay at the manufacturer-recommended threshold of ≥1,500 ng/mL compared to LC-MS/MS. We assessed associations of the point-of-care uTFV assay, and DBS TFV-DP concentrations with concurrent viraemia, and with retention-in-care by 16 weeks post-enrolment. Results Of 196 adults median age was 44 years, 127 (64.8%) were female, and 191 (97.4%) were receiving TDF. 185 (94.4%) had detectable point-of-care uTFV, which had high sensitivity (99.5%, 95% CI 96.5-100%) and moderate specificity (76.9%, 95% CI 46.0-93.8%) for detecting uTFV ≥1,500 ng/mL. Two participants had concurrent viraemia ≥1,000 copies/mL; of these 50.0% (95% CI 9.4-90.5) had undetectable point-of-care uTFV, and 100% (95% CI 19.7-100) had low TFV-DP <483 fmol/punch. Among participants without viraemia 97.4% (95% CI 93.6-99.0) had detectable uTFV, and 98.1% (95.3-99.6) had high TFV-DP ≥483 fmol/punch. Point-of-care uTFV and DBS TFV-DP were not associated with retention-in-care. Conclusions The point-of-care uTFV assay demonstrated high sensitivity and moderate specificity to detect uTFV. Over 95% of people without viraemia had detectable point-of-care uTFV or high DBS TFV-DP levels respectively, but these were not associated with 16-week retention-in-care.
Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.
Contrôle bibliographique ouvert
DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.
- Titre Crossref
- Diagnostic accuracy of point-of-care urine tenofovir test, and associations between metrics of tenofovir use and treatment outcomes in a community ART programme
- Date Crossref
- 14/08/2026
- Éditeur
- openRxiv
- Type
- posted-content
Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude et ne compte pas comme une seconde source scientifique indépendante.
Institutions déclarées
Une affiliation ne permet pas de déduire la nationalité d’un auteur.