Intra- and inter-rater reliability of ultrasound assessment of rectus femoris muscle thickness by physiotherapists: influence of operator experience

0Citations signalées, ce qui n’est pas une note de qualité
1Institutions déclarées
1Pays d’affiliation déclarés

Rattachement africain : it. Niveau de preuve : code pays fourni par la source.

Le résumé fourni par la source

Background Rehabilitative ultrasound imaging is increasingly used in physiotherapy as an objective method for muscle assessment. However, its reliability across different levels of operator experience requires further clarification. Objective To evaluate the intra- and inter-rater reliability of rectus femoris thickness measurements among expert and novice physiotherapists. Methods Four physiotherapists (two experts, two novices) assessed rectus femoris thickness in healthy individuals. Reliability was evaluated using intraclass correlation coefficients (ICC) and limits of agreement (LoA). The standard error of measurement (SEM) and minimal detectable change (MDC) were calculated to quantify measurement precision. Results Both expert raters demonstrated good-to-excellent intra-rater reliability (Rater A: ICC 2 , 1 0.84–0.98; Rater B: ICC 2 , 1 0.81–0.98). Novice raters showed good-to-excellent (Rater C: ICC 2 , 1 0.80–0.98) and moderate-to-excellent reliability (Rater D: ICC 2 , 1 0.73–0.97). The pooled SEM was 0.48 mm, with no clinically relevant differences between raters. The MDC was 1.34 mm. Inter-rater reliability was moderate-to-good for single measurements and good-to-excellent for average measurements, with similar patterns across expertise groups. LoA ranged from –3.13 to 3.05 mm for experts and from –3.25 to 2.09 mm for novices. Conclusions Ultrasound assessment of rectus femoris thickness demonstrates high intra-rater reliability among physiotherapists, supporting its use in clinical practice. Our preliminary findings suggest that novice raters may approach expert-level reliability following a short training protocol. Inter-rater reliability was acceptable and improved when averaging multiple measurements. For longitudinal monitoring, assessments are likely to be more consistent when performed by the same operator; when this is not feasible, averaging repeated measurements may help reduce inter-operator variability.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Le contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Intra- and inter-rater reliability of ultrasound assessment of rectus femoris muscle thickness by physiotherapists: influence of operator experience
Date Crossref
01/10/2026
Éditeur
Elsevier BV
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.

Les institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Les sujets associés

Nutrition and Health in AgingBalance, Gait, and Falls PreventionSports injuries and prevention

BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.