Conduction system vs. biventricular pacing in heart failure with reduced ejection fraction: a meta-analysis of randomized controlled trials
Résumé fourni par la source
AIMS: Conduction system pacing (CSP) has emerged as a physiologic alternative to cardiac resynchronization therapy (CRT) with biventricular pacing (BiVP) in heart failure with reduced ejection fraction (HFrEF), yet its comparative effects remain uncertain. This meta-analysis sought to compare outcomes of CSP vs. BiVP in patients with HFrEF undergoing CRT. METHODS AND RESULTS: MEDLINE, Embase, Scopus, and the Cochrane Database were searched through 4 May 2026. Randomized controlled trials (RCTs) were synthesized using random-effects meta-analysis. Thirteen RCTs including 1320 participants were analysed (657 CSP, 663 BiVP). Conduction system pacing was associated with a lower risk of the composite of hospitalization for heart failure (HHF) or all-cause mortality compared with BiVP (46 vs. 83 events; odds ratio [OR] 0.51, 95% confidence interval [CI] 0.28-0.93). No significant differences were observed for HHF alone (OR 0.68, 95% CI 0.36-1.27) or all-cause mortality (OR 0.75, 95% CI 0.36-1.58). Conduction system pacing was associated with greater improvement in the 6-min walk distance (mean difference [MD] 21.53 m, 95% CI 4.33-38.73) and New York Heart Association functional class (standardized mean difference [SMD] -0.27, 95% CI -0.47 to -0.07), but not quality of life. Conduction system pacing also reduced QRS duration compared with BiVP (MD -10.94 ms, 95% CI -17.55 to -4.34), with no significant differences in left ventricular ejection fraction, left ventricular end-systolic volume, overall pacing threshold, total procedure time, fluoroscopy time, any complication, or reintervention. CONCLUSION: In patients with HFrEF undergoing CRT, CSP is associated with lower composite risk of HHF or all-cause mortality compared with BiVP. Conduction system pacing is also associated with improved functional capacity, without significant differences in safety or procedural outcomes.
Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.
Contrôle bibliographique ouvert
DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.
- Titre Crossref
- Conduction system vs. biventricular pacing in heart failure with reduced ejection fraction: a meta-analysis of randomized controlled trials
- Date Crossref
- 01/08/2026
- Éditeur
- Oxford University Press (OUP)
- Type
- journal-article
Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude et ne compte pas comme une seconde source scientifique indépendante.
Institutions déclarées
Une affiliation ne permet pas de déduire la nationalité d’un auteur.