Aller au contenu principal
2026 article

Continuous Glucose Monitoring Systems in Europe: Regulatory Landscape and Certification Process Challenges Under MDR 2017/745

0Citations signalées — pas une note de qualité
2Institutions déclarées
2Pays d’affiliation déclarés

Résumé fourni par la source

AIMS: To analyze the certification process for continuous glucose monitoring (CGM) systems in Europe under the applicable Medical Device Regulation (MDR) 2017/745 and to highlight potential issues that may impact the reliability of CGM devices following introduction to the market. METHODS: We undertook a detailed review of MDR 2017/745 using publicly available European Commission information portals to assess the current implementation status. Specifically, we examined where checks and balances intended to ensure the accuracy and safety of CGM devices were not in place and identify where delays in implementation of key functions may reduce transparency and efficacy of the Conformité Européenne certification process. RESULTS: Key elements of the MDR have not been implemented, creating inertia for manufacturers and the Notified Bodies that undertake conformity assessments. Delays in implementing the European Databank on Medical Devices (EUDAMED), which was designed to harmonize pre- and post-marketing collection of medical device information, have limited access to critical evidence for Notified Bodies and delayed strengthening of post-market surveillance. CONCLUSIONS: The current process of CGM Conformity Assessment under MDR 2017/745 limits access to regulatory submissions of clinical evidence reports, reference methodologies and other documentation necessary for CGM devices to be assessed as safe, accurate and effective in the populations of people with diabetes in whom they may be used. Additional checks and balances are required to increase transparency of the conformity assessment process prior to CE marking, and improve the traceability of CGM devices in the post-marketing period.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé, mais le titre doit être comparé manuellement.

Titre Crossref
Continuous Glucose Monitoring Systems in Europe: Regulatory Landscape and Certification Process Challenges Under <scp>MDR</scp> 2017/745
Date Crossref
13/08/2026
Éditeur
Wiley
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude et ne compte pas comme une seconde source scientifique indépendante.

Institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Sujets associés

Diabetes Management and ResearchHyperglycemia and glycemic control in critically ill and hospitalized patientsPharmacovigilance and Adverse Drug Reactions

BNTIC News n’est pas le producteur de ces données. Recherche à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, ROR et la Banque mondiale, sans clé ; OpenAlex reste optionnel. Aucun service payant requis, aucune donnée externe enregistrée en base. Sources et limites.