Aller au contenu principal
Accès ouvert déclaré 2026 article

Twelve Fused Models by Fusing Four Types of Transformer-Based Tuners on Three Base UNet Architectures for Carotid Wall Segmentation and Plaque Burden/Intima-Media Thickness Measurements in Ultrasound Scans: A Scientific Validation Study

0Citations signalées — pas une note de qualité
15Institutions déclarées
7Pays d’affiliation déclarés

Résumé fourni par la source

Background/Objectives: UNet-based models dominate medical image segmentation. Transformers have been added as an internal variant to these UNet-based architectures to improve feature learning. However, they have limitations in generalization and computational efficiency. Motivated by this idea, we have designed a two-stage novel hybrid segmentation framework, where tuners are added in cascade to the base architectures. Methods: Three sets of base UNets were designed, namely: B1: UNet1p, B2: UNet2p, and B3:UNet3p, and four sets of transformer-based tuners were designed, namely: T1:Transformer-augmented UNet, T2: Attention-guided UNet, T3: Swin Transformer-based UNet, and T4: Pyramid-based network, leading to 12 fused systems that combine three base UNets and four Tuners, namely: F1: B1 + T1, F2: B1 + T2, F3: B1 + T3, F4: B1 + T4; F5: B2 + T1, F6: B2 + T2, F7: B2 + T3, F8: B2 + T4, F9: B3 + T1, F10: B3 + T2, F11: B3 + T3, F12: B3 + T4. Results: The two-hybrid segmentation models are more effective and reliable than the single-stage UNet architecture. B3 + T4 achieved a Dice of 94.14% and Jaccard of 88.7%, surpassing prior baselines by 4.2% and 6.8%. It reduced cIMTE to 0.014 mm, a 36% improvement and the lowest reported to date, with cLIE and cMAE errors lowered by 40%. Conclusions: All 12 hybrid automated transformer-based models are highly accurate and reliable for wall segmentation in carotid ultrasound; they are a powerful paradigm for cardiovascular risk.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Twelve Fused Models by Fusing Four Types of Transformer-Based Tuners on Three Base UNet Architectures for Carotid Wall Segmentation and Plaque Burden/Intima-Media Thickness Measurements in Ultrasound Scans: A Scientific Validation Study
Date Crossref
12/08/2026
Éditeur
MDPI AG
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude et ne compte pas comme une seconde source scientifique indépendante.

Institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Sujets associés

Cerebrovascular and Carotid Artery DiseasesCardiovascular Health and Disease PreventionUltrasound Imaging and Elastography

BNTIC News n’est pas le producteur de ces données. Recherche à la demande dans Crossref et Europe PMC, sans clé ; OpenAlex reste optionnel. Aucun service payant requis, aucune réponse conservée. Sources et limites.