Aller au contenu principal
Accès ouvert déclaré 2026 article

Diagnostic agreement between Rhinoswabs and joint nose and throat swabs for the detection of influenza and SARS-CoV-2 among symptomatic ambulatory patients in Hong Kong

0Citations signalées — pas une note de qualité
2Institutions déclarées
1Pays d’affiliation déclarés

Résumé fourni par la source

BACKGROUND: Accurate detection of respiratory viruses relies on appropriate sample collection, but whether joint nose and throat sampling is necessary for high diagnostic performance or whether nose sampling alone can provide comparable results remains uncertain. OBJECTIVES: We evaluated the diagnostic agreement between joint nose and throat swabs (NTS) and Rhinoswab (RhinoMed, Cremorne, Australia), a novel anterior nasal swab for RT-qPCR detection of respiratory viruses among symptomatic outpatients. STUDY DESIGN: Outpatients with febrile acute respiratory illness were enrolled at a clinic in Hong Kong and paired joint NTS and Rhinoswab samples were tested by reverse transcription polymerase chain reaction (RT-qPCR) for influenza A, influenza B, SARS-CoV-2 and human ribonuclease P (RNase P) as an internal control. Diagnostic agreement and RT-qPCR Ct values were compared between the paired samples. RESULTS: Between May 2023 and April 2024, 488 participants provided paired samples. Overall concordance between Rhinoswab and NTS was 98.0% (95% CI: 96.3% to 99.0%) for influenza A, 99.0% (95% CI: 97.6% to 99.7%) for influenza B, and 99.0% (95% CI: 97.6% to 99.7%) for SARS-CoV-2. Cohen's kappa also indicated high agreement for all viruses: 0.95 (95% CI: 0.92 to 0.98) for influenza A, 0.94 (95% CI: 0.88 to 0.99) for influenza B, and 0.92 (95% CI: 0.85 to 0.99) for SARS-CoV-2. Ct values from Rhinoswab were moderately correlated with NTS for all three viruses and RNase P. The majority of discordant samples had Ct values of 30 and above (16/18, 88.9%). CONCLUSIONS: Rhinoswabs achieved high agreement with joint NTS for RT-qPCR detection of influenza and SARS-CoV-2. Given their minimal invasiveness Rhinoswabs are a viable alternative specimen type for supervised respiratory virus testing.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Diagnostic agreement between Rhinoswabs and joint nose and throat swabs for the detection of influenza and SARS-CoV-2 among symptomatic ambulatory patients in Hong Kong
Date Crossref
11/08/2026
Éditeur
Public Library of Science (PLoS)
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude et ne compte pas comme une seconde source scientifique indépendante.

Institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Sujets associés

SARS-CoV-2 detection and testingRespiratory viral infections researchBiosensors and Analytical Detection

BNTIC News n’est pas le producteur de ces données. Recherche à la demande dans Crossref et Europe PMC, sans clé ; OpenAlex reste optionnel. Aucun service payant requis, aucune réponse conservée. Sources et limites.