Aller au contenu principal
Accès ouvert déclaré 2026 article

Clinical Performance of an Isofocal Toric Intraocular Lens with Double C-Loop Haptics: A Multicenter Retrospective Study

0Citations signalées, ce qui n’est pas une note de qualité
6Institutions déclarées
4Pays d’affiliation déclarés

Rattachement africain : gb, jp, fr, it. Niveau de preuve : code pays fourni par la source.

Le résumé fourni par la source

Purpose: To evaluate clinical outcomes in eyes with pre-existing astigmatism undergoing cataract surgery or refractive lens exchange with the implantation of an isofocal optic-design toric intraocular lens (IOL) with double C-loop haptics. Method: This multicenter retrospective study comprised 100 eyes (65 patients) implanted with the Isopure Serenity toric IOL (BVI, Inc.) conducted across four sites. Postoperative evaluation at between 2 and 3 months included manifest refraction, monocular uncorrected and distance corrected visual acuity (UDVA and CDVA), monocular uncorrected and distance corrected intermediate visual acuity (UIVA and DCIVA, at 80 and 66 cm), monocular uncorrected and distance corrected near visual acuity (UNVA and DCNVA, at 40 cm), binocular defocus curve and rotational stability. Results: Manifest refraction spherical equivalent and refractive astigmatism were -0.24±0.41D and -0.36±0.36D, respectively. About 79% and 97% of eyes were within ±0.50D and ±1.00D, respectively, and 80% and 96% of eyes were ≤0.50D and ≤1.00D of refractive cylinder, respectively. At distance vision, the mean monocular CDVA was -0.02±0.06 logMAR and 92.93% of eyes showed a CDVA of ≥20/20. At intermediate vision, the mean monocular DCIVA values were 0.10±0.07 and 0.17±0.10 logMAR at 80 cm and 66 cm, respectively; and 96.92% and 88.33% of eyes showed a DCIVA of ≥20/32 at 80 cm and 66 cm, respectively. At near vision, the mean monocular DCNVA was 0.31±0.08 logMAR and 75.44% of eyes showed a DCNVA of ≥20/40. The binocular depth of focus range was approximately 1.50D. The mean absolute IOL rotation was 2.73±2.58 degrees with all eyes having a rotation of <10 degrees. Conclusions: Eyes with pre-existing astigmatism implanted with the Isopure Serenity toric IOL showed good distance visual acuity and functional intermediate vision, with high refractive accuracy and good rotational stability following cataract and refractive lens exchange surgery.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Le contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Clinical Performance of an Isofocal Toric Intraocular Lens with Double C-Loop Haptics: A Multicenter Retrospective Study
Date Crossref
01/08/2026
Éditeur
Informa UK Limited
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.

Les institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Les sujets associés

Ophthalmology and Visual Impairment StudiesIntraocular Surgery and LensesOcular Disorders and Treatments

BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.