Autonomous Velocity Encoding ( VENC ) Selection Improves Precision of Quantitative Flow Measurement

0Citations signalées — pas une note de qualité
3Institutions déclarées
2Pays d’affiliation déclarés

Résumé fourni par la source

BACKGROUND: The optimal velocity encoding limit (VENC) in phase contrast MRI is subject-specific because it depends on peak flow rate and the presence of flow jets. Currently, VENC is set manually with limited prior knowledge of the peak velocity. Setting the correct VENC might improve measurement precision or shorten scan times. PURPOSE: To evaluate a workflow for autonomous selection of the optimal VENC without technologist interaction. STUDY TYPE: Prospective and retrospective. POPULATION: The retrospective cohort included 254 scans from 113 patients (47 ± 14 years, 58 female) and 18 healthy volunteers (34 ± 15 years, 10 female). The prospective cohort included 5 patients with abnormal flow (47 ± 19 years, 2 female) and 10 healthy volunteers (28 ± 7 years, 6 female). FIELD STRENGTH/SEQUENCE: 1.5 T, 0.55 T; Cartesian gradient echo phase-contrast sequence. ASSESSMENT: A workflow has been designed to autonomously estimate and prescribe the optimal VENC. A 30s free-breathing calibration scan was followed by automatic estimation of the maximum velocity (Vmax) in < 6 s. The calculated optimal VENC was then automatically applied in the subsequent flow measurement without operator intervention. The target VENC:Vmax ratio was 1.1-1.25 according to consensus statements. STATISTICAL TESTS: Shapiro-Wilk test, nonparametric two-sided bootstrap with 90% confidence intervals, Wilcoxon signed-rank test, paired t-test. Holm correction was applied to prespecified pairwise comparisons. p < 0.05 was considered significant. RESULTS: :Vmax = 1.99 ± 0.41). Optimized VENC improved measurement precision, reducing velocity standard deviation by 41.9% ± 8.0%, and enabling shorter scan time to approximately 1/3 compared with default VENC 200 cm/s while maintaining equivalent velocity-to-noise performance. DATA CONCLUSION: Inline autonomous VENC selection improved flow-measurement precision, simplified the acquisition workflow, and reduced scan time at 0.55 T. EVIDENCE LEVEL: 2. TECHNICAL EFFICACY: 1.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé, mais le titre doit être comparé manuellement.

Titre Crossref
Autonomous Velocity Encoding ( <scp>VENC</scp> ) Selection Improves Precision of Quantitative Flow Measurement
Date Crossref
07/08/2026
Éditeur
Wiley
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude et ne compte pas comme une seconde source scientifique indépendante.

Institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Sujets associés

Advanced MRI Techniques and ApplicationsCerebrospinal fluid and hydrocephalusHemodynamic Monitoring and Therapy

BNTIC News n’est pas le producteur de ces données. Recherche à la demande dans Crossref et Europe PMC, sans clé ; OpenAlex reste optionnel. Aucun service payant requis, aucune réponse conservée. Sources et limites.