Aller au contenu principal
Accès ouvert déclaré 2026 article

Developing the NewAthena X-IFU Cryogenic AntiCoincidence Detector (CryoAC): From Microfabrication Process Standardization to Cryogenic Functional Verification Toward TRL5

0Citations signalées — pas une note de qualité
9Institutions déclarées
1Pays d’affiliation déclarés

Résumé fourni par la source

The Cryogenic Anticoincidence (CryoAC) detector is a critical subsystem designed to reduce the particle background for the X-ray Integral Field Unit (X-IFU) instrument onboard the NewAthena space observatory, the next ESA X-ray Large mission. Advancing this technology to Technology Readiness Level 5 (TRL5) requires a unified validation spanning both cleanroom microfabrication repeatability and mK low temperature operational performance. This work presents the complete development cycle of the Demonstration Model 1.2 (DM 1.2), which is aimed at completing the TRL5 demonstration path featured by all the critical technologies operating simultaneously. First, single-process verification protocols were established for Iridium pulsed laser deposition, Reactive Ion Etching (RIE), and deep silicon trenching via the Bosch process. Second, three identical single-pixel prototypes were fabricated and subjected to mK characterization. Four-wire resistance measurement results confirmed a 2/3 production yield against strict design targets (TC ~100 mK). Finally, functional testing at a bath temperature of 50 mK using a VTT FAB4 SQUID readout demonstrated excellent performance, including a low-energy threshold of ~0.6 keV, a pixel power dissipation of 5.15 nW, and an energy resolution ΔEFWHM = 735 eV at 6 keV. These combined achievements successfully validate the entire manufacturing and operational baseline against all primary space mission requirements. This paper has to be considered as a review of the CryoAC technology path toward the TRL5 achievement; main findings will be reported and discussed. Details are relegated to other papers.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Developing the NewAthena X-IFU Cryogenic AntiCoincidence Detector (CryoAC): From Microfabrication Process Standardization to Cryogenic Functional Verification Toward TRL5
Date Crossref
06/08/2026
Éditeur
MDPI AG
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude et ne compte pas comme une seconde source scientifique indépendante.

Institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Sujets associés

Particle Detector Development and PerformanceSuperconducting and THz Device TechnologyRadiation Detection and Scintillator Technologies

BNTIC News n’est pas le producteur de ces données. Recherche à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, ROR et la Banque mondiale, sans clé ; OpenAlex reste optionnel. Aucun service payant requis, aucune donnée externe enregistrée en base. Sources et limites.