Aller au contenu principal
Accès ouvert déclaré 2026 article

Turning bubbles into sensors: foam-based detection of paraquat in water

0Citations signalées, ce qui n’est pas une note de qualité
6Institutions déclarées
2Pays d’affiliation déclarés

Rattachement africain : de, fr. Niveau de preuve : code pays fourni par la source.

Le résumé fourni par la source

Intensive global agricultural growth has increased pesticide use, raising concerns about water contamination. Paraquat (PQ), a highly water-soluble, nonselective herbicide used in over 130 countries, poses serious risks to human health because its high solubility and long environmental half-life make it a persistent pollutant. Although conventional analytical methods provide excellent sensitivity, they require expensive instruments and complex sample preparation, limiting their practicality for on-site applications. Here, we present a fast, visual, on-site paraquat detection strategy based on smart liquid foam systems. The method exploits a highly selective host-guest complex between water soluble pillar[5]arene (WS-P[5]A) and PQ. First, WS-P[5]A hosts are loaded with the bio-based surfactant sucrose laurate (SL), which interacts less with WS-P[5]A than PQ. Secondly, PQ is added which replaces SL due to the higher binding constant between WS-P[5]A and PQ. Upon replacement of SL by PQ, surfactant is released which enables foam generation by hand-shaking. Changes in foam height correlate with PQ concentration, providing an intuitive visual readout. We demonstrate a high selective method even in the presence of competing contaminants, and we validate its performance across multiple water types. This supramolecular foam sensor could offer a simple, selective, rapid, and low-cost approach for the preliminary detection of paraquat in contaminated water. The proposed foam-based method is designed as an on-site screening tool that can be used by virtually anyone without specialized equipment, technical expertise, or laboratory infrastructure. Foam formation provides a straightforward visual indication of the presence of paraquat, enabling fast field-based assessment. If paraquat is detected qualitatively, quantification can subsequently be performed using well-established analytical techniques.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Le contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Turning bubbles into sensors: foam-based detection of paraquat in water
Date Crossref
01/01/2027
Éditeur
Elsevier BV
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.

Les institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Les sujets associés

Paraquat toxicity studies and treatmentsPickering emulsions and particle stabilizationEnvironmental remediation with nanomaterials

BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.