Favorable Results Following Patella Fracture Fixation With 2.7 mm Variable Angle Locking Plates: A Technical Note and Case Series
Rattachement africain : us. Niveau de preuve : code pays fourni par la source.
Le résumé fourni par la source
Introduction: The primary objective of this study was to describe a technique using a 2.7 mm variable-angle (VA) locking plate fixation in combination with ex situ and in situ plate contouring, a high screw density, a “homerun” screw, and routine postoperative immobilization to obtain reliable outcomes following patella fractures. The secondary objectives were to determine the rate of postoperative complications and the range of motion at final follow-up, as well as the time to weight-bearing as tolerated and the time to range-of-motion as tolerated. Methods: All consecutive adult patients treated with a 2.7 mm VA locking plate for a patella fracture (AO/OTA 34) between January 2021 and January 2025 were retrospectively identified from one Level 1 trauma center. The use of 2.7 mm VA locking plates and augmented fixation was determined through operative reports and radiographs. Results: Thirty-seven patients treated with the technique were identified. One patient (2.7%, 95% CI: 0.07%-14%) experienced construct failure, and 4 patients (11%, 95% CI: 3.0%-25%) returned to the operating room (2 manipulations under anesthesia, 1 intra-articular screw removal, and 1 symptomatic hardware removal). No patients experienced infection or nonunion. At final orthopedic follow-up, the median RUST score was 12/12 (IQR=11 to 12). Conclusions: The described technique resulted in low rates of loss of fixation, implant failure, and removal of symptomatic implants, as well as reliable healing, following patella fracture fixation with a 2.7 mm VA locking plate.
Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.
Le contrôle bibliographique ouvert
DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.
- Titre Crossref
- Favorable Results Following Patella Fracture Fixation With 2.7 mm Variable Angle Locking Plates: A Technical Note and Case Series
- Date Crossref
- 05/08/2026
- Éditeur
- Ovid Technologies (Wolters Kluwer Health)
- Type
- journal-article
Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.
Les institutions déclarées
Une affiliation ne permet pas de déduire la nationalité d’un auteur.