A New Era in Early Postoperative OCT: Swept-Source Versus Spectral-Domain in Gas-Filled Eyes
Rattachement africain : it. Niveau de preuve : code pays fourni par la source.
Le résumé fourni par la source
Objectives: This study aims to compare the imaging performance of spectral-domain optical coherence tomography (SD-OCT) and swept-source OCT (SS-OCT) in the early postoperative assessment of patients undergoing vitreoretinal surgery with intraocular gas or air tamponade. Methods: Seventeen eyes of 17 patients who underwent pars plana vitrectomy with either sulfur hexafluoride (SF6, 20%) or air tamponade were prospectively enrolled. All patients underwent OCT imaging on postoperative day 1 using both the SD-OCT system and the SS-OCT platform, without pharmacological mydriasis. Images were independently evaluated by two experienced ophthalmologists based on the ability to delineate four prespecified anatomical layers: inner retinal layers, ellipsoid zone (EZ), retinal pigment epithelium (RPE) and choroid. Images were classified as adequate quality if two or more of these structures were identifiable. Results: SS-OCT provided adequate-quality images in all 17 eyes (100%), with complete visualization of the inner retinal layers, EZ, RPE, and choroid in 15 eyes (88.2%). In contrast, SD-OCT yielded adequate-quality images in only three of 17 eyes (17.6%), demonstrating marked signal attenuation, interface artifacts, and inability to resolve deeper retinal structures in most cases. No difference in imaging performance was observed between SF6 and air tamponade subgroups. Conclusions: SS-OCT demonstrates markedly superior imaging performance in gas-filled eyes on postoperative day 1 compared to SD-OCT, primarily attributable to its longer wavelength, reduced sensitivity roll-off, and superior penetration through optically challenging media. These findings suggest that SS-OCT may offer meaningful advantages for early postoperative monitoring following vitreoretinal surgery with tamponade; confirmation in larger prospective cohorts with clinical-outcome correlation is warranted before it can be recommended as the preferred modality.
Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.
Le contrôle bibliographique ouvert
DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.
- Titre Crossref
- A New Era in Early Postoperative OCT: Swept-Source Versus Spectral-Domain in Gas-Filled Eyes
- Date Crossref
- 02/08/2026
- Éditeur
- MDPI AG
- Type
- journal-article
Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.
Les institutions déclarées
Une affiliation ne permet pas de déduire la nationalité d’un auteur.