A beam-hardening predictive index (BHPI) for simulation-guided spectral optimisation in laboratory X-ray CT

0Citations signalées — pas une note de qualité
11Institutions déclarées
3Pays d’affiliation déclarés

Résumé fourni par la source

Beam hardening remains a major source of imaging artefacts in X-ray computed tomography (XCT), particularly with multi-material samples. We propose here the mitigation of beam hardening not as a reactive correction, but as part of a more proactive scan planning. We introduce a pre-acquisition scalar metric, called beam-hardening predictive index (BHPI), and demonstrates its use as a primary metric for selecting X-ray spectra that minimise beam-hardening effects, with peak signal-to-noise ratio (PSNR) serving as a secondary image-quality constraint, whilst avoid photon starvation, under- and over-exposure. A simulation-based spectral analysis was performed using a digital twin of the imaging system to evaluate tube-voltage and filtration combinations. Representative optimal and suboptimal spectra were identified from the BHPI–PSNR performance landscape and subsequently used to acquire experimental XCT data for (i) 3D-printed cyanoacrylate-infiltrated powder, (ii) steel-lead-resin, (iii) zirconium-vanadium alloy-resin, and (iv) copper wire specimens. The BHPI-guided spectra consistently produced reconstructions with reduced beam-hardening artefacts and improved intensity uniformity. For the copper wire, BHPI alone identified a superior configuration despite lower PSNR, demonstrating that BHPI captures beam-hardening sensitivity that PSNR cannot. These improvements also resulted in more stable multi-level Otsu segmentation under optimised conditions. Supporting metrics showed that noise performance was not degraded: SNR remained comparable or improved, and total variation (TV) decreased under the optimised spectra. Overall, the results demonstrated that BHPI provides a practical and experimentally reliable criterion for identifying acquisition parameters that reduce beam-hardening artefacts while maintaining acceptable image quality, offering a foundation for beam-hardening-aware scan planning in XCT. The resulting improvement in image quality also facilitates more reliable and computationally efficient segmentation, reducing dependence on advanced correction algorithms.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
A beam-hardening predictive index (BHPI) for simulation-guided spectral optimisation in laboratory X-ray CT
Date Crossref
01/09/2026
Éditeur
Elsevier BV
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude et ne compte pas comme une seconde source scientifique indépendante.

Institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Sujets associés

Advanced X-ray and CT ImagingMedical Imaging Techniques and ApplicationsCardiac Imaging and Diagnostics

BNTIC News n’est pas le producteur de ces données. Recherche à la demande dans Crossref et Europe PMC, sans clé ; OpenAlex reste optionnel. Aucun service payant requis, aucune réponse conservée. Sources et limites.