Disulfide‐Linked Symmetrical Polydiacetylene as Visualized Temperature Sensor for Heatstroke Monitor
Rattachement africain : cn. Niveau de preuve : code pays fourni par la source.
Le résumé fourni par la source
Body temperature is a key physiological indicator, requiring continuous, full-range monitoring from normothermia to hyperthermia for effective heatstroke management. To address the limitations of mercury thermometers and existing sensors in visualized real-time screening, three monomers S-1, S-2, and S-3 featuring flexible aliphatic chains and ester terminals, anhydride terminals, and aromatic rings with amide hydrogen bonds and π-π stacking are designed and polymerized into Poly(S-1), Poly(S-2), and Poly(S-3), respectively. Among these polydiacetylenes (PDAs) with symmetric functionalization, Poly(S-1) exhibits a multi-step, naked-eye-visible thermochromic transition within 35°C-43°C, attributed to its flexible aliphatic chains and ester linkages that enable side-chain motion and main-chain conformational changes at low temperatures. In contrast, the rigid structural motifs present in Poly(S-2) and Poly(S-3) introduce stronger intermolecular forces and higher energy barriers, necessitating elevated temperatures to induce comparable thermochromic transitions. Notably, Poly(S-1) is successfully fabricated into a functional patch; its irreversible thermochromic nature within the physiological range meets the requirements of disposable medical devices, helping to prevent cross-infection and facilitating temperature recording. This study enables precise tuning of the thermochromic temperature of PDA materials, expands their applications in biomedical monitoring and smart responsive materials, and offers design insights and theoretical foundations for developing next-generation visual body temperature sensors.
Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.
Le contrôle bibliographique ouvert
DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.
- Titre Crossref
- Disulfide‐Linked Symmetrical Polydiacetylene as Visualized Temperature Sensor for Heatstroke Monitor
- Date Crossref
- 28/07/2026
- Éditeur
- Wiley
- Type
- journal-article
Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.
Les institutions déclarées
Une affiliation ne permet pas de déduire la nationalité d’un auteur.