Aller au contenu principal
Accès ouvert déclaré 2026 preprint

Rapid diagnosis of fever etiology using wearable temperature monitoring and machine learning

0Citations signalées, ce qui n’est pas une note de qualité
6Institutions déclarées
1Pays d’affiliation déclarés

Rattachement africain : us. Niveau de preuve : code pays fourni par la source.

Le résumé fourni par la source

Introduction: Distinct temperature patterns have long been recognized to correlate with fevers of differing etiologies. While the use of wearable sensors for high-frequency temperature monitoring (HFTM) on a near minute-by-minute basis has been shown to detect fevers earlier than standard-of-care nursing vital sign assessments in hospitalized patients, leveraging these high-resolution datasets to computationally identify unique digital signatures for real-time diagnosis of underlying fever etiology has not been widely explored. Diagnostic uncertainty is common in patients undergoing hematopoietic stem cell transplantation (HCT), with only 20-30% of febrile neutropenic episodes being microbiologically documented. We hypothesized that unique temperature patterns extracted from HFTM data collected during episodes of febrile neutropenia could be used to develop a supervised machine learning classifier capable of accurately predicting underlying fever etiology in HCT patients. Methods: We analyzed 68 clinically independent fever episodes recorded in HCT patients (n=90) outfitted with an FDA-cleared wireless temperature sensor (TempTraq®, BlueSpark Technologies) that measured axillary temperature every 2 minutes throughout hospitalization. Time-series features were extracted from temperature traces spanning 1 hour before to 3 hours after fever onset and used to train a suite of machine-learning models to distinguish engraftment fevers from other fever etiologies. Model training and evaluation were performed using repeated stratified 5-fold patient-level cross-validation, yielding 100 train-test evaluations. Results: Among all classification models, the logistic regression classifier provided the best overall performance and interpretability, achieving 94% specificity (95% CI, 0.84-1.0) for identifying engraftment fevers with a mean AUROC of 0.88 ± 0.10. Feature importance analysis demonstrated that both clinical variables and HFTM-derived temperature dynamics contributed to model performance, with a strong reliance on time-series features captured within the first 4 hours of fever onset. Conclusion: Our study provides a demonstration that continuous temperature data collected from patients outfitted with wearable sensors can be leveraged not only for early fever detection but also for machine learning-based diagnosis of fever etiology. These findings suggest that dynamic temperature patterns contain clinically meaningful physiologic information that with further studies could support real-time diagnostic decision-making and guide safe de-escalation of empiric antibiotics during febrile neutropenia in patients undergoing intensive cancer therapy.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Le contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Rapid diagnosis of fever etiology using wearable temperature monitoring and machine learning
Date Crossref
28/07/2026
Éditeur
openRxiv
Type
posted-content

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.

Les institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Les sujets associés

Neutropenia and Cancer InfectionsSepsis Diagnosis and TreatmentThermal Regulation in Medicine

BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.