Objective Bayesian Analysis of Micronucleus Biodosimetry Data for Radiation Protection and Low-Dose Medical Applica-Tions of Ionizing Radiation

0Citations signalées, ce qui n’est pas une note de qualité
0Institutions déclarées
0Pays d’affiliation déclarés

Le résumé fourni par la source

Jeffreys‑rule Bayesian inference for the Poisson mean was retrospectively applied to cytokinesis‑block micronucleus (CBMN) data from four studies conducted in a single laboratory (2001–2026), covering ionising‑radiation exposures in human lymphocytes and an ¹³¹I biodosimetry study (29 experimental groups). The CBMN assay is widely used for cytogenetic biodosimetry and for evaluating radioprotective agents, but classical analysis of net micronucleus (MN) yield becomes unreliable when effective radioprotectors reduce MN frequencies towards background, leading to near‑zero or negative net counts with poorly characterised uncertainty. In our reanalysis, the Bayesian correction systematically modified magnitude-of-protection and dose-reduction estimates in low-count, high‑protection conditions in comparison with the classical approach. Using Bayesian net counts to recalculate standard radioprotective metrics revealed that, while the overall ranking of radioprotective potency was preserved, Bayesian magnitudes of protection and dose reduction factors were consistently lower than their classical counterparts for the most effective radioprotectors administered before irradiation, providing more conservative efficacy estimates with quantified uncertainty. In the ¹³¹I biodosimetry cohort and in patients undergoing diagnostic nuclear medicine procedures, post‑exposure MN yields remained within the spontaneous background variability of the assay, and the Bayesian framework is fully compatible with the practical absence of detectable chromosomal damage at the doses used in routine clinical practice. Taken together, these results demonstrate that Jeffreys‑rule Bayesian inference provides a statistically coherent and practically feasible framework for CBMN analysis in the low‑count regime, stabilising net MN estimates, avoiding artefactual negative values and supplying confidence intervals for radioprotective efficacy metrics. As a concrete methodological recommendation, Bayesian analysis should be adopted as the default approach whenever post‑exposure MN counts are within approximately a factor of two of background, with classical methods remaining adequate at higher count levels.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Le contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Objective Bayesian Analysis of Micronucleus Biodosimetry Data for Radiation Protection and Low-Dose Medical Applica-Tions of Ionizing Radiation
Date Crossref
24/07/2026
Éditeur
MDPI AG
Type
posted-content

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.

Les sujets associés

Carcinogens and Genotoxicity AssessmentEffects of Radiation ExposureDNA Repair Mechanisms

BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.