Clinical utility of the twiist Automated Insulin Delivery System: first study with twiist

0Citations signalées, ce qui n’est pas une note de qualité
2Institutions déclarées
1Pays d’affiliation déclarés

Rattachement africain : us. Niveau de preuve : code pays fourni par la source.

Le résumé fourni par la source

INTRODUCTION: Randomized controlled trials and real-world studies have demonstrated that automated insulin delivery (AID) systems enhance glycemic control and mitigate hypoglycemia risk in individuals with type 1 diabetes. This study evaluated the safety, effectiveness, and usability of the twiist AID System on glycemic outcomes in adults with type 1 diabetes. RESEARCH DESIGN AND METHODS: This 8-week, prospective, single-center, single-arm study included 20 adults with type 1 diabetes. The primary outcome measures were the percent of time spent in established continuous glucose monitoring (CGM) glycemic target ranges at 8 weeks. The primary efficacy outcome was percent time in range (%TIR; 70-180 mg/dL) at 8 weeks. Secondary outcomes were the change in glucose pre-occlusion detection; the effects of total daily insulin delivery (TDD) on glucose pre- and post-occlusion detection; the effect of Max basal ratio on %TIR; the effect of users' correction range on %TIR; and change in glycated haemoglobin (HbA1c). Changes in TDD and body weight were also assessed. RESULTS: 19 participants completed the study. At 8 weeks, the mean %TIR was 70.3±15.5%. Participants achieved or maintained glycemic targets for all CGM metrics except time above >250 mg/dL. A total of 67 occlusion events occurred in 15 participants. These events were detected within 30 min of rising glucose. Higher max basal ratio settings were associated with higher %TIR. The %TIR for participants with a correction range <100 mg/dL was 79.2±13.4% vs 67.2±15.0% for those with a correction range >100 mg/dL. HbA1c levels decreased (-0.4%±0.5%) in participants with baseline HbA1c >7%. A slight increase in TDD (1.3±16.2 U) and a decrease in body weight (-0.09±2.9 kg) were observed. No serious adverse events were reported. CONCLUSIONS: Eight-week use of twiist enabled participants to achieve or maintain established glycemic targets and suggests the system's ability to detect occlusions before clinically significant glucose rise regardless of TDD. Larger and longer term studies are needed.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Le contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Clinical utility of the twiist Automated Insulin Delivery System: first study with twiist
Date Crossref
01/07/2026
Éditeur
BMJ
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.

Les institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Les sujets associés

Diabetes Management and ResearchHyperglycemia and glycemic control in critically ill and hospitalized patientsMobile Health and mHealth Applications

BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.