Skin dosimetry in megavoltage radiotherapy using hydrogenated amorphous silicon on a tissue-equivalent flexible substrate
Résumé fourni par la source
Abstract Acute skin toxicity after radiation treatments highlights the need for improved dose monitoring and measurement, as the treatment planning system does not accurately estimate skin dose. Wearable radiation detectors may be the solution for most in vivo dosimetry needs, but they require innovative materials. The purpose of this work is to overcome the challenges that limit accurate skin dosimetry by exploring the use of hydrogenated amorphous silicon (a-Si:H) fabricated on a flexible polyimide substrate for direct radiation detection. The a-Si:H detector was fabricated on a 125 μ m polyimide substrate with a thickness of 3.6–10 μ m. The detector’s response to the build-up region of the percentage depth dose (PDD) of the MV photon beam was compared to Geant4 radiation transport simulations and benchmarked to Attix ionization chamber measurements. Angular dependency and surface field factors at the phantom surface were compared to Attix IC. The PDD measurement is within 2% of Geant4’s simulation and the Attix chamber’s response from 150 μ m to 25 mm in a plastic water phantom. All samples showed linear dose responses with 0.37% reproducibility. The a-Si:H device matches the Attix chamber for surface field factor measurements (6–10 MV photon beams, for 5 to 25 cm field sizes). The angular dependence (−60° to +60°) compared to the Attix IC confirms the sensor’s WED of 150 ± 5 µ m. This study demonstrates that a-Si:H sensors on flexible plastic substrates have a potential for accurate surface dose measurements and agree with reference detectors. This thin, flexible detector provides real time measurements and is stable under high radiation doses. The possibility to assemble with ease an array of a-Si:H pixels over large areas with different sizes and shapes, makes this technology attractive for in vivo dosimetry.
Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.
Contrôle bibliographique ouvert
DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.
- Titre Crossref
- Skin dosimetry in megavoltage radiotherapy using hydrogenated amorphous silicon on a tissue-equivalent flexible substrate
- Date Crossref
- 06/08/2026
- Éditeur
- IOP Publishing
- Type
- journal-article
Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude et ne compte pas comme une seconde source scientifique indépendante.
Institutions déclarées
Une affiliation ne permet pas de déduire la nationalité d’un auteur.