Aller au contenu principal
Accès ouvert déclaré 2026 article

Chronocoulometric Quantification of DNA Surface Coverage on Electrochemically Functionalized MoS2 Interfaces

0Citations signalées — pas une note de qualité
3Institutions déclarées
1Pays d’affiliation déclarés

Résumé fourni par la source

Abstract Quantitative control of the surface coverage of nucleic acid is critical for the development of reproducible and sensitive biosensing platforms. However, establishing covalently defined biointerfaces on molybdenum disulfide (MoS2) remains challenging due to the chemical inertness of its basal planes. Here, we present a rapid, environmentally benign solid-state electrografting strategy to functionalize MoS2 surface that enables rapid immobilization and direct quantification of DNA constructs. Liquid-exfoliated MoS2 nanosheets deposited on indium tin oxide (ITO) substrates were modified via electroreduction of halogenated carboxylic acids to activate the MoS2 surface with carboxylate groups, followed by conjugation of amine-terminated DNA and surface passivation with aminohexanol. The covalently linked DNA/MoS2 interface was characterized using surface probe and electrochemical techniques. Chronocoulometry was employed for the direct quantification of single- and double-stranded constructs with matched and mismatched base pairs. Single-stranded DNA exhibits Langmuir adsorption with a maximum surface density Γmax = 23 ± 3 × 1013 molecules cm–2 and a dissociation constant Kd = 1.1 nM, indicating high-affinity and reproducible probe immobilization. The electrografted iodobenzoic linker promotes slightly higher surface density (26 ± 6 × 1013 molecules•cm–2) of the probe DNA relative to aliphatic analogues. In contrast, double-stranded constructs, including matched and mismatched sequences, show less than half the surface coverage of the probe DNA due to a larger footprint and, in some cases, due to structural distortion. Overall, structurally rigid electrografted linkers show better probe coverage and may be considered a reliable tool for designing biosensors on MoS2 surface.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Chronocoulometric Quantification of DNA Surface Coverage on Electrochemically Functionalized MoS2 Interfaces
Date Crossref
18/07/2026
Éditeur
American Chemical Society (ACS)
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude et ne compte pas comme une seconde source scientifique indépendante.

Institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Sujets associés

Advanced biosensing and bioanalysis techniquesElectrochemical Analysis and ApplicationsMolecular Junctions and Nanostructures

BNTIC News n’est pas le producteur de ces données. Recherche à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, ROR et la Banque mondiale, sans clé ; OpenAlex reste optionnel. Aucun service payant requis, aucune donnée externe enregistrée en base. Sources et limites.