Agreement and workflow efficiency of AI-based coronary artery calcification quantification in lung cancer screening: Comparison with semi-automated and visual assessment

0Citations signalées — pas une note de qualité
2Institutions déclarées
1Pays d’affiliation déclarés

Résumé fourni par la source

Objectives To evaluate agreement and workflow implications of fully automated AI-based coronary artery calcification (CAC) quantification on non-ECG-gated low-dose CT in lung cancer screening, compared with semi-automated (SA) and visual assessment. Materials and methods In this retrospective single-center study, 323 participants (55.7% male; median age 61 years; 52–79 years) undergoing low-dose CT for lung cancer screening were included. CAC was quantified using SA and AI-based Agatston scoring. Two readers performed visual grading. Agreement between SA and AI was assessed using intraclass correlation coefficient (ICC), Spearman correlation, and Bland-Altman analysis. Categorical agreement (CAD-RADS 2.0 plaque burden) and CAC detection were evaluated using weighted Cohen's κ and diagnostic metrics. CAC processing times for were compared. Results AI-based and semi-automated Agatston scores showed excellent agreement (ICC 0.96) and strong correlation (Spearman r = 0.97), with a small bias (21.5) and moderate limits of agreement. AI achieved high diagnostic performance for excluding CAC (sensitivity 0.97, 95%-CI, 0.92–0.99; specificity 0.91, 95%-CI, 0.86–0.94). Categorical agreement between AI and SA was almost perfect (κ 0.92) and higher than agreement between SA and visual assessment (κ 0.84 and 0.68). SA scoring required substantially longer processing time (102.0 ± 95.7 s) compared with visual assessment (15.5 ± 6.0 s and 24.2 ± 7.4 s; p < 0.001). Conclusion AI-based CAC quantification on non-ECG-gated low-dose CT demonstrates excellent agreement compared to semi-automated scoring, with higher categorical agreement than visual assessment and no requirement for manual scoring. AI-based approaches may facilitate standardized and scalable CAC reporting in lung cancer screening without additional reading time.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Agreement and workflow efficiency of AI-based coronary artery calcification quantification in lung cancer screening: Comparison with semi-automated and visual assessment
Date Crossref
01/12/2026
Éditeur
Elsevier BV
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude et ne compte pas comme une seconde source scientifique indépendante.

Institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Sujets associés

Cardiac Imaging and DiagnosticsLung Cancer Diagnosis and TreatmentRadiomics and Machine Learning in Medical Imaging

BNTIC News n’est pas le producteur de ces données. Recherche à la demande dans Crossref et Europe PMC, sans clé ; OpenAlex reste optionnel. Aucun service payant requis, aucune réponse conservée. Sources et limites.