Aller au contenu principal
Accès ouvert déclaré 2026 article

Optical coherence tomography for carotid artery plaque: a standardised imaging and analysis methodology

0Citations signalées, ce qui n’est pas une note de qualité
3Institutions déclarées
2Pays d’affiliation déclarés

Rattachement africain : cn, ca. Niveau de preuve : code pays fourni par la source.

Le résumé fourni par la source

BACKGROUND: Stroke remains a leading cause of morbidity and mortality, with carotid atherosclerosis representing a major contributor. High-resolution evaluation of plaque characteristics is critical for risk stratification and therapeutic guidance. However, reliable methodologies for assessments are limited. Optical coherence tomography (OCT) provides superior resolution, yet standardised protocols for carotid artery imaging are lacking. OBJECTIVE: This study aimed to develop and validate a standardised methodology for the acquisition and analysis of carotid artery plaque using OCT imaging. METHODS: Sixty-four patients with internal carotid artery stenosis from the HERALD trial who underwent paired OCT imaging were included. A standardised non-occlusive protocol was employed to accommodate carotid anatomy. Key plaque features-minimum fibrous cap thickness (FCT), maximum lipid arc, calcification, minimum lumen area, intraplaque vessels, dissection and cholesterol crystals-were assessed by three independent, blinded observers. Fibrous cap volume (FCV) was calculated using an AI-driven dual-coordinate framework. Statistical analyses included intraclass correlation coefficients (ICC) for continuous variables, Fleiss' kappa for categorical variables, Bland-Altman analysis for inter-observer agreement and Pearson correlation to assess relationships between variables. RESULTS: Analysis of 134 OCT pullbacks demonstrated excellent inter-observer reproducibility for minimum FCT (ICC=0.901), maximum lipid arc (ICC=0.812), and minimum lumen area (ICC=0.909). All observers achieved excellent intra-observer consistency. Bland-Altman analysis confirmed high agreement. Agreement for qualitative features was excellent for cholesterol crystals (κ=0.957), intraplaque vessels (κ=0.955), and dissections (κ=0.988) and moderately high for calcification (κ=0.848). FCV measurement using the AI framework showed good concordance with manual segmentation (mean Dice coefficient=0.73). A weak positive correlation was observed between changes in FCV and minimum FCT (r=0.296, p=0.024). CONCLUSIONS: This study establishes a comprehensive and standardised OCT methodology for carotid plaque imaging, demonstrating excellent reproducibility in quantifying key morphological and high-risk features.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Le contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Optical coherence tomography for carotid artery plaque: a standardised imaging and analysis methodology
Date Crossref
17/07/2026
Éditeur
BMJ
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.

Les institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Les sujets associés

Optical Coherence Tomography ApplicationsCerebrovascular and Carotid Artery DiseasesCoronary Interventions and Diagnostics

BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.