Inter‐Observer Variability of Gerd‐Related Metrics on High‐Resolution Manometry and Calculation of the Milan Score
Rattachement africain : it, us, id, my, es, gb, jp, mx. Niveau de preuve : code pays fourni par la source.
Le résumé fourni par la source
BACKGROUND: High-resolution manometry (HRM) is increasingly used to assess risk of gastroesophageal reflux disease (GERD). The Milan Score (MS) integrates four HRM variables-EGJ morphology, EGJ contractile integral (EGJ-CI), ineffective esophageal motility (IEM), and straight leg raise (SLR) response-to predict pathological esophageal acid exposure. The inter-observer reproducibility of the MS and its components has never been formally assessed. METHODS: A total of 50 consecutive HRM plots from patients undergoing evaluation for suspected GERD at a tertiary referral center were distributed to a multicenter pool of esophageal experts for blind review. Participants assessed EGJ type, EGJ-CI, IEM, and SLR response; the MS and corresponding GERD risk were automatically calculated. Inter-observer variability was evaluated using Fleiss' κ for categorical variables and Kendall's coefficient for continuous variables. MS accuracy was assessed by comparing calculated scores against MII-pH results. RESULTS: Twenty-three esophageal experts from 16 international institutions reviewed all 50 plots. Agreement was fair for EGJ morphology (κ = 0.321), moderate for SLR (W = 0.531), and good for IEM (κ = 0.638), EGJ-CI (W = 0.675) and the final MS (W = 0.641). Median plot-level concordance between MS and pH-impedance study was 71.74% [IQR 51.08%]; median reader accuracy for Milan Score was 64% [IQR 12%], ranging from 54% to 80%. CONCLUSIONS: Inter-observer variability of the Milan Score is good across a diverse international cohort of esophageal experts, supporting its reproducibility as a clinical tool. However, agreement for individual parameters was heterogeneous, and the assessment of EGJ morphology and the SLR maneuver achieved only fair-to-moderate agreement, highlighting the need for improved standardization.
Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.
Le contrôle bibliographique ouvert
DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.
- Titre Crossref
- Inter‐Observer Variability of Gerd‐Related Metrics on High‐Resolution Manometry and Calculation of the Milan Score
- Date Crossref
- 01/07/2026
- Éditeur
- Wiley
- Type
- journal-article
Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.
Les institutions déclarées
Une affiliation ne permet pas de déduire la nationalité d’un auteur.