Aller au contenu principal
Accès ouvert déclaré 2026 article

Air purifiers in classrooms for infection control: a pilot study including a randomized multiple crossover trial to evaluate effectiveness in reducing particulate matter

0Citations signalées, ce qui n’est pas une note de qualité
3Institutions déclarées
1Pays d’affiliation déclarés

Rattachement africain : no. Niveau de preuve : code pays fourni par la source.

Le résumé fourni par la source

Abstract Background Air purifiers with high-efficiency particulate air (HEPA) filters aim to reduce particulate matter from the air, including infectious aerosols, potentially lowering airborne disease transmission in classrooms. This pilot study, informing a larger randomized trial (RCT), explored the acceptability and feasibility of air purifiers in classrooms, and estimated their effect on particulate matter (PM 2.5 ) concentration. Methods This study, conducted in schools in the greater Oslo area, Norway, from January to April 2023, consisted of two parts lasting 6 and 9 weeks, respectively. In part 1, eligible primary school classrooms received either ceiling-mounted or portable purifiers. In part 2, we conducted a three-arm randomized multiple crossover trial of ceiling-mounted versus portable purifiers versus no air purification. Schools with three classrooms on the same floor with adequate space for air purifiers were eligible. We evaluated acceptability and feasibility of installing and operating air purifiers by collecting interview data from students (part 1) and teachers (parts 1 and 2). The feasibility of collecting consent and questionnaires from students’ legal guardians and student absences from municipality records was explored. We evaluated superiority of air purification versus no air purification and noninferiority of portable versus ceiling-mounted air purifiers on PM 2.5 concentration using sensor measured air quality data. Results Five primary schools (five classrooms) and one adult education school (three classrooms) participated in parts 1 and 2 of the study, respectively. Ceiling-mounted and portable air purifiers were feasible to install and operate and were well-accepted by students ( n = 11) and teachers ( n = 7). No harms were reported. Consent and questionnaires were collected from 23 of 114 students’ legal guardians. Collecting absence data from municipality records was feasible, although inconsistencies in teachers’ recording affected weekly accuracy. Air purification was superior to no air purification in reducing PM 2.5 concentration ( p = 0.011), and portable purifiers were noninferior to ceiling-mounted units ( p < 0.001) and significantly reduced PM 2.5 compared to no air purification (rate ratio 0.71; 95% CI 0.57–0.89). Conclusions Installing and operating air purifiers in classrooms is feasible and acceptable. Portable purifiers are user-friendly and reduce PM 2.5 concentration. It was challenging to obtain consent from students’ legal guardians to collect absence data; municipality records proved more practical. A larger RCT on air purifier effectiveness in schools will be feasible if data collection challenges can be overcome. Trial registration NCT06374316 (retrospectively registered 15 April 2024)

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Le contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Air purifiers in classrooms for infection control: a pilot study including a randomized multiple crossover trial to evaluate effectiveness in reducing particulate matter
Date Crossref
11/07/2026
Éditeur
Springer Science and Business Media LLC
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.

Où se fait cette recherche

  • Norwegian Institute of Public Health Centre for Epidemic Interventions Research (CEIR) pays non établi dans la notice
    Organisme public
  • OsloMet – Oslo Metropolitan University pays non établi dans la notice
    Université ou école supérieure
  • SINTEF pays non établi dans la notice
    Structure de recherche
  • Faculty of Health Sciences pays non établi dans la notice
    Université ou école supérieure

Centre for Epidemic Interventions Research (CEIR) — Norwegian Institute of Public Health, OsloMet – Oslo Metropolitan University et SINTEF, avec 1 autre affiliation.

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Les sujets associés

Indoor Air Quality and Microbial ExposureInfection Control and VentilationChild Nutrition and Water Access

BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.