Visual Outcomes Following Cataract Surgery With Custom-Made Toric IOLs for the Correction of High Corneal Astigmatism

0Citations signalées, ce qui n’est pas une note de qualité
5Institutions déclarées
3Pays d’affiliation déclarés

Rattachement africain : il, dk, us. Niveau de preuve : code pays fourni par la source.

Le résumé fourni par la source

Purpose: To describe the refractive results of cataract surgery in patients with high corneal astigmatism treated with implantation of custom-made toric intraocular lenses (IOLs). Methods: This retrospective cohort analysis of eyes implanted with high-cylinder (≥6.75 diopters [D]) custom-made toric IOLs was conducted at Rabin Medical Center, Petach Tikva, Israel. A control group of eyes implanted with standard toric IOLs (1.50 to 3.75 D) was also included. Postoperative IOL misalignment, uncorrected distance visual acuity (UDVA), residual refractive astigmatism (RA), and the prediction error (PE) of the toric IOL calculation using the Barrett Toric Calculator were assessed. Results: Twenty-two eyes of 22 patients were included. The mean ± standard deviation toric power was 9.67 ± 3.51 D (range: 6.75 to 19.00 D). Diagnoses included pellucid marginal degeneration (n = 7), keratoconus (n = 4), post-keratoplasty astigmatism (n = 3), and previous pterygium excision (n = 2). The mean postoperative UDVA was 0.28 ± 0.19 logarithm of the minimum angle of resolution (Snellen: 20/38). Mean absolute astigmatism decreased from 7.88 ± 3.15 D preoperatively (corneal) to 0.76 ± 0.87 D postoperatively (refractive) ( P < .001). One eye required redialing due to a 17° misalignment. Compared with the control group (41 eyes), the high-cylinder toric IOL group showed a slightly lower UDVA (20/30, P = .024) and a non-significant trend toward higher RA (0.58 ± 0.50, P = .930), as well as a significantly worse RA-PE, in both vector magnitude (1.47 vs. 0.62, P = .027) and vector dispersion (total bivariate variance 2.67 vs 0.40, px < 0.001 and py = 0.006). Conclusions: Customized high-cylinder toric IOLs significantly improve UDVA and reduce RA in eyes with extreme corneal astigmatism. Although slightly inferior to standard toric IOLs, they provide an effective treatment option for astigmatic correction in complex corneal pathologies with a central and relatively regular astigmatic component.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Le contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Visual Outcomes Following Cataract Surgery With Custom-Made Toric IOLs for the Correction of High Corneal Astigmatism
Date Crossref
01/07/2026
Éditeur
SLACK, Inc.
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.

Les institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Les sujets associés

Ophthalmology and Visual Impairment StudiesCorneal surgery and disordersIntraocular Surgery and Lenses

BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.