Aller au contenu principal
Accès ouvert déclaré 2026 article

Changes in SSM Assessed via 100 Hz ‐ VCTE Are Associated With Acute HVPG ‐Response to i.v. Propranolol: A European Multicentre Study

0Citations signalées, ce qui n’est pas une note de qualité
5Institutions déclarées
3Pays d’affiliation déclarés

Rattachement africain : at, it, pt. Niveau de preuve : code pays fourni par la source.

Le résumé fourni par la source

BACKGROUND: The acute hepatic venous pressure gradient (HVPG)-response to i.v. propranolol predicts outcomes in patients with advanced chronic liver disease (ACLD) and clinically significant portal hypertension (CSPH). While non-invasive tests (NIT) to monitor non-selective beta-blocker (NSBB)-induced HVPG changes are lacking, spleen stiffness measurement (SSM) has shown promising results as a surrogate for HVPG. This study aimed to assess the correlation between changes in SSM at 100 Hz and HVPG upon acute i.v. propranolol. METHODS: ACLD patients with CSPH undergoing paired HVPG and SSM-100 Hz assessments pre- and post-i.v. propranolol (0.15 mg/kg) at three expert centres between 2019 and 2024 were included. HVPG-response was defined as a ≥ 10% decrease in HVPG. RESULTS: ) were included. Most had alcohol-related liver disease (ALD)/metabolic-associated liver disease (59.6%) or metabolic-associated steatotic liver disease (11.7%). The median HVPG decreased from 17 (Q1-Q3: 15-20) mmHg to 16 (Q1-Q3: 12-19) mmHg post-NSBB (p < 0.001), with 45.7% achieving an acute HVPG-response. SSM decreased by -8.7 ([Q1-Q3: -19.2; -0.2] kPa, p < 0.001). HVPG-responders had a significant SSM decrease (-12.4 [Q1-Q3: -26.3; -5.6] kPa, p < 0.001), while non-responders showed no change. A moderate correlation between relative changes in SSM and HVPG was observed (Spearman's ρ: 0.387; p < 0.001). Relative change in SSM achieved an area under the receiver operating characteristic curve (AUROC) of 0.717 (95% CI: 0.614-0.820, p < 0.001) for diagnosing HVPG-response. CONCLUSION: SSM-100 Hz dynamics are associated with HVPG changes upon i.v. propranolol administration. Although the discriminative ability of changes in SSM was insufficient for clinical use, they may serve as a surrogate of efficacy in clinical trials investigating medical therapies for portal hypertension.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Le contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé, mais le titre doit être comparé manuellement.

Titre Crossref
Changes in <scp>SSM</scp> Assessed via <scp>100 Hz</scp> ‐ <scp>VCTE</scp> Are Associated With Acute <scp>HVPG</scp> ‐Response to i.v. Propranolol: A European Multicentre Study
Date Crossref
09/07/2026
Éditeur
Wiley
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.

Les institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Les sujets associés

Liver Disease and TransplantationHemodynamic Monitoring and TherapyNon-Invasive Vital Sign Monitoring

BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.