Aller au contenu principal
Accès ouvert déclaré 2026 preprint

ImputeECG: Deep Learning Reconstruction of Complete 12-Lead Electrocardiograms from Incomplete Recordings for Cardiac Assessment

0Citations signalées, ce qui n’est pas une note de qualité
0Institutions déclarées
0Pays d’affiliation déclarés

Le résumé fourni par la source

Complete digital 12-lead electrocardiograms (ECGs) are essential for AI-enabled cardiovascular assessment, yet many clinical ECG records, particularly those digitized from ECG images, remain incomplete because of short display formats, incomplete waveform digitization, lead loss, or signal corruption. We developed ImputeECG, a mask-conditioned one-dimensional Transformer autoencoder that completes 12-lead, 10-s ECGs while retaining all observed samples. The model was trained on PTB-XL and evaluated on PTB-XL and CPSC2018 under simulated incomplete settings, with additional real-world validation in a 43,633-record Kailuan clinical cohort after ECG image digitization. Metrics were computed over originally missing regions, with analyses of morphology and downstream diagnostic utility. On PTB-XL, ImputeECG reduced missing-region MAE by 41.7-51.0% and MSE by 54.0-63.7% versus the strongest baseline, with lower errors in R-peak timing, RR interval, QRS duration, QT interval, and P-wave, QRS-complex, and T-wave reconstruction. On CPSC2018, ImputeECG reduced MAE by 49.7-51.9%, supporting external generalization. In downstream multi-label classification, ImputeECG restored performance to 92.28% AUROC and 33.88% AUPRC in the most incomplete PTB-XL setting, approaching complete-ECG performance. On CPSC2018, completed ECGs achieved 94.75-95.89% AUROC and 78.83-81.86% AUPRC across settings. In Kailuan, ECG completion improved zero-shot sex prediction AUROC from 82.6% to 85.8% and reduced age prediction MAE from 10.72 to 9.87 years after image-based ECG digitization. These findings support ECG completion as a practical strategy for converting incomplete ECG records into AI-ready 12-lead, 10-s digital signals and extending the usable scope of ECG archives for digital cardiac assessment.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Le contrôle bibliographique ouvert

La source scientifique ouverte est momentanément indisponible.

Les sujets associés

ECG Monitoring and AnalysisCardiac electrophysiology and arrhythmiasAtrial Fibrillation Management and Outcomes

BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.