Assessing iatrogenic atrial septal defect as a primary unloading strategy in acute myocardial infarction using computational and swine model
Rattachement africain : il. Niveau de preuve : code pays fourni par la source.
Le résumé fourni par la source
Primary-unloading of the left ventricle in Acute Myocardial Infarction (AMI) may reduce infarct size and resultant heart-failure occurrence. Existing methods, such as percutaneous axial flow pumps, pose cost and complication challenges. Hemodynamic parameters from AMI patients in published cohorts were applied in a real-time cardiovascular computer-model simulating AMI. Hemodynamic changes were tracked after induction of 2.5-12.5 mm Iatrogenic Atrial-Septal Defect (iASD). Subsequently, in-vivo evaluation in swine was performed by inducing AMI using percutaneous-balloon occlusion of the left coronary system. A 7.5 mm iASD was created via transeptal balloon septostomy, repeatedly opened, and occluded, while advanced hemodynamic parameters were monitored. The computer simulation demonstrated a decrease in mean(± SEM) pulmonary capillary wedge pressure (PCWP) of 8.05 ± 0.7 mmHg from a baseline to iASD (21.2 ± 8.3 vs. 13.2 ± 4.2 mmHg, p < 0.001), reaching a maximum reduction of 8.05 ± 1.04at 7.5 mm (13.2 ± 3.9 mmHg). Mean Arterial Pressure (MAP) was reduced from baseline compared to iASD intervention (94.7 ± 14.8 vs. 84.4 ± 13.6 mmHg, p < 0.001) with no difference between iASD sizes. The cardiac output (CO) was reduced by a mean(± SEM) 0.46 ± 0.15 L/min from baseline compared to mean iASD interventions (4.05 ± 1.28 vs. 3.59 ± 1.16 L/min, p = 0.001). In the swine model, 60 measurements were taken. The mean(± SEM) PCWP was increased by 7.23 ± 1.0 from baseline during coronary obstruction (14.72 ± 1.6 vs. 21.95 ± 3.9 mmHg, p < 0.01) and decreased by 4.85 ± 1.1 with the iASD (17.1 ± 2.7 mmHg, p = 0.039). The iASD didn't cause hemodynamic compromise, as there was no reduction in MAP (43.6 ± 13.5 vs. 48.3 ± 12.0 mmHg, p > 0.99) or CO (2.6 ± 0.5 vs. 2.3 ± 0.2 L/min, p > 0.99) compared to coronary obstruction without iASD. In conclusion, iASD unloaded the left ventricle in AMI without causing immediate hemodynamic compromise in this preliminary study. These findings highlight the potential of iASD as a feasible primary-unloading method that warrants further investigation regarding its safety and cost-effectiveness.
Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.
Le contrôle bibliographique ouvert
DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.
- Titre Crossref
- Assessing iatrogenic atrial septal defect as a primary unloading strategy in acute myocardial infarction using computational and swine model
- Date Crossref
- 05/07/2026
- Éditeur
- Springer Science and Business Media LLC
- Type
- journal-article
Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.
Où se fait cette recherche
-
Hebrew University of Jerusalem pays non établi dans la noticeUniversité ou école supérieure
-
Hadassah Medical Center pays non établi dans la noticeÉtablissement de santé
-
Israel Defense Forces Medical Corps pays non établi dans la noticeOrganisme public
-
Faculty of Medicine Department of Military Medicine and "Tzameret" pays non établi dans la noticeUniversité ou école supérieure
Hebrew University of Jerusalem, Hadassah Medical Center et Israel Defense Forces Medical Corps, avec 1 autre affiliation.
Une affiliation ne permet pas de déduire la nationalité d’un auteur.