Aller au contenu principal
Accès ouvert déclaré 2026 article

Impact of Higher Versus Lower Blood Pressure Targets on Pulmonary Vascular Hemodynamics During Intensive Care After Out‐of‐Hospital Cardiac Arrest

1Citations signalées, ce qui n’est pas une note de qualité
5Institutions déclarées
1Pays d’affiliation déclarés

Rattachement africain : dk. Niveau de preuve : code pays fourni par la source.

Le résumé fourni par la source

BACKGROUND: Hemodynamic management after out-of-hospital cardiac arrest (OHCA) is critical, yet the impact of vasopressor-driven mean arterial pressure (MAP) targets on pulmonary circulation and right ventricular (RV) function remains unclear. METHODS: In this substudy of the randomized, double-blinded BOX trial, comatose OHCA survivors were allocated to low (63 mmHg) or high (77 mmHg) MAP targets. Pulmonary artery catheters (PAC) were used for serial hemodynamic assessment for 48 h after Intensive Care Unit admission. The primary endpoint was calculated pulmonary vascular resistance (PVR), secondary endpoints included pulmonary capillary wedge pressure (PCWP), pulmonary artery pulsatility index (PAPi), and RV cardiac power output (RV-CPO)-a measurement of RV pumping function. RESULTS: Among 730 included patients (median time randomization to PAC insertion 1.3 h), mPAP was consistently higher in the high-MAP group (mean difference 1.11-1.71 mmHg, 95% CI range 0.12-2.59). Calculated PVR was transiently lower in the high-MAP group during the first 24 h (mean difference -0.16 to -0.30, 95% CI range -0.31 to 0.11), before converging between groups. RV-CPO was lower in the low-MAP group throughout the observation period (mean difference 0.01-0.04 W [95% range 0.00-0.07], with the largest difference at 48 h. PCWP decreased in both groups but was significantly lower in the low-MAP group during the first 12 h (mean difference 1.06-1.40 mmHg, 95% CI range 0.25-2.38). CONCLUSIONS: In comatose OHCA survivors, targeting a higher MAP increased pulmonary artery pressures, PCWP, RV-CPO, heart rate, and cardiac output. The proportionally greater increase in cardiac output over pulmonary artery pressures resulted in a decreased calculated PVR. TRIAL REGISTRATION: ClinicalTrials.gov identifier: NCT03141099. EDITORIAL COMMENT: In this secondary analysis of a subgroup in the BOX out of hospital cardiac arrest treatment trial for oxygen level targets, blood pressure treatment target levels, higher or lower were analyzed, including central circulatory outcomes, using a pulmonary artery catheter. The higher blood pressure target group had accompanying higher pulmonary artery pressures and cardiac output, with initially a small reduction in calculated pulmonary vascular resistance.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Le contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Impact of Higher Versus Lower Blood Pressure Targets on Pulmonary Vascular Hemodynamics During Intensive Care After Out‐of‐Hospital Cardiac Arrest
Date Crossref
03/07/2026
Éditeur
Wiley
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.

Les institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Les sujets associés

Hemodynamic Monitoring and TherapyCardiac Arrest and ResuscitationMechanical Circulatory Support Devices

BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.