Single-shot spinal buprenorphine with low-dose bupivacaine for labor analgesia: A prospective interventional study on maternal and fetal outcomes
Rattachement africain : in. Niveau de preuve : code pays fourni par la source.
Le résumé fourni par la source
Background: Labor pain can be intense and have an impact on both the mother and the fetus. Single-shot spinal analgesia using buprenorphine and low-dose bupivacaine is a simple, effective, and cost-efficient alternative to epidural analgesia. Aim: To investigate the effects of single-dose spinal analgesia with buprenorphine (ITN) and bupivacaine on maternal and fetal outcomes Materials and Methods: This prospective interventional study was conducted in the Department of Obstetrics and Gynecology, SMGS Hospital, Jammu, over one year from October 2021 to September 2022. A total of 100 parturients in active labor with cervical dilatation ?3 cm were enrolled and divided into two groups. The study group received intrathecal buprenorphine 50 ?g with bupivacaine 1 mg, while the control group underwent natural labor without analgesia. Maternal hemodynamic parameters, labor characteristics, mode of delivery, fetal outcomes, Visual Analogue Scale (VAS) scores, and complications were assessed. Results: The second stage of labor was significantly shorter in the study group (23.29 ± 17.35 min) compared with the control group (37.34 ± 31.56 min) (p=0.0089). VAS scores significantly decreased within 5 minutes following spinal analgesia (1.34 ± 0.74 vs 8.35 ± 0.52; p<0.0001). Mean duration of analgesia was 224.6 ± 143.6 minutes. No significant differences were observed in cesarean section rate, instrumental delivery, CTG abnormalities, or APGAR scores between the groups. Maternal side effects were minimal and manageable. Conclusion: Single-shot intrathecal labor analgesia using buprenorphine with low-dose bupivacaine provides rapid, effective, and prolonged pain relief without adverse maternal or neonatal outcomes. It is a safe, economical, and practical alternative to epidural analgesia, especially in low-resource settings.
Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.
Le contrôle bibliographique ouvert
DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.
- Titre Crossref
- Single-shot spinal buprenorphine with low-dose bupivacaine for labor analgesia: A prospective interventional study on maternal and fetal outcomes
- Date Crossref
- 01/07/2026
- Éditeur
- Comprehensive Publications
- Type
- journal-article
Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.
Les institutions déclarées
Une affiliation ne permet pas de déduire la nationalité d’un auteur.