Progressive reduction in complications of cryoballoon pulmonary vein isolation for atrial fibrillation
Rattachement africain : br, it. Niveau de preuve : code pays fourni par la source.
Le résumé fourni par la source
AIMS: Cryoballoon pulmonary vein isolation (CB-PVI) has become an established treatment for atrial fibrillation and, recently, it has been proposed as first-line therapy for the treatment of paroxysmal atrial fibrillation. Nevertheless, some concerns remain regarding the safety of this thermal energy-based approach. This prospective analysis aimed to assess the procedural complication rate of CB-PVI in a large cohort of consecutive patients over a nearly 13-year period. METHODS: Data from consecutive patients treated with CB-PVI for atrial fibrillation between April 2012 and November 2024 in 35 institutions were analyzed. All complications occurring from patient admission up to 3 months postprocedure were recorded. RESULTS: Eight thousand five hundred and thirty-one patients were enrolled (27.2% women, mean age 60.8 ± 10.5 years, 75.7% with paroxysmal atrial fibrillation), and 211 of them (2.49%) experienced at least one procedural adverse event related to CB-PVI. Of note, one cardiac tamponade event led to a sudden cardiovascular death (0.01%). A statistically significant reduction in complication rates was observed amongst three cohorts of product usage: from 2012 to 2015 ( n = 1326 patients, 5.0%), from 2016 to 2019 ( n = 3487 patients, 2.5%), and from 2020 to 2024 ( n = 3718 patients, 1.6%; P < 0.001). Multivariate logistic regression analysis identified use of the Arctic Front Advance PRO balloon as a significant protective factor against complications [OR 0.26 (0.17-0.40), P < 0.001], whereas female sex emerged as the strongest predictor of adverse events [OR 1.54 (1.11-2.13), P < 0.01]. CONCLUSION: CB-PVI for atrial fibrillation ablation has proven to be a well tolerated procedure, with a steadily decreasing complication rate over time.
Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.
Le contrôle bibliographique ouvert
DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.
- Titre Crossref
- Progressive reduction in complications of cryoballoon pulmonary vein isolation for atrial fibrillation
- Date Crossref
- 01/06/2026
- Éditeur
- Ovid Technologies (Wolters Kluwer Health)
- Type
- journal-article
Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.
Les institutions déclarées
Une affiliation ne permet pas de déduire la nationalité d’un auteur.