Standardized low-flow ventilation with PEEP maintenance during bronchoscopy in mechanically ventilated ICU patients: a pilot trial

0Citations signalées — pas une note de qualité
3Institutions déclarées
1Pays d’affiliation déclarés

Résumé fourni par la source

Fiberoptic bronchoscopy in mechanically ventilated ICU patients can markedly increase airway resistance and peak inspiratory pressure (PIP), limit effective tidal volume delivery, and provoke transient hypoxemia, hypercapnia, dynamic hyperinflation, and hemodynamic instability. However, per-procedural ventilator management remains heterogeneous. This single-center trial with before-and-after design assessed the feasibility and safety of implementing a standardized low-flow ventilation protocol, and characterized its physiological effects (particularly peak inspiratory pressure), during bronchoscopy in adults intubated and ventilated in volume-assist-control mode. During the observational phase ( n = 36), ventilator settings reflected usual practice (increased pressure alarm and reduced PEEP; no routine flow reduction). Following a 1-month training period, the intervention phase ( n = 35) implemented an inspiratory flow rate of 20 L/min, unchanged PEEP, and a reduced respiratory rate to achieve an I:E ratio of 1:2. Physiologic and ventilator data were automatically recorded at 1-min intervals. The primary endpoint was peak inspiratory pressure (PIP), a physiological endpoint reflecting the mechanical effect of the intervention. Secondary endpoints included minute ventilation (MV), end-tidal CO2 (EtCO2), oxygenation metrics, ventilator alarms, and hypotension, feasibility and procedural safety. PIP decreased substantially (45 [35, 65] cmH2O vs. 82 [59, 93] cmH 2 O; p < 0.001), resulting in a reduction in the time spent with pressure alarms (3.4% vs. 24%; p < 0.0001). However, MV (5.2 [4.6, 5.9] L/min vs. 6.4 [4.1, 7.3] L/min; p = 0.2), and EtCO2 (36 [30, 40] mmHg vs. 31 [27, 39] mmHg; p = 0.4) did not differ significantly. PEEP was maintained in the intervention group (8 [6, 10] cmH2O vs. 2 [0, 5] cmH 2 O; p = 0.001). The protocol was demonstrated short-term procedural safety signals, as average SpO 2 (98.9 [93.7, 100.0]% vs. 99.9 [96.8, 100.0], p = 0.082), and hypotension incidence (8.6% vs. 14%; p = 0.7) did not differ significantly. This protocol implementation study demonstrates that standardized low-flow ventilation with PEEP maintenance is feasible and safe during bronchoscopy in mechanically ventilated patients, with a significant reduction in peak inspiratory pressure as a robust mechanical signal. Alveolar ventilation and hemodynamic tolerance were preserved. These findings support the conduct of further research to evaluate clinical outcomes.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Standardized low-flow ventilation with PEEP maintenance during bronchoscopy in mechanically ventilated ICU patients: a pilot trial
Date Crossref
21/06/2026
Éditeur
Springer Science and Business Media LLC
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude et ne compte pas comme une seconde source scientifique indépendante.

Institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Sujets associés

Respiratory Support and MechanismsNosocomial Infections in ICUAirway Management and Intubation Techniques

BNTIC News n’est pas le producteur de ces données. Recherche à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, ROR et la Banque mondiale, sans clé ; OpenAlex reste optionnel. Aucun service payant requis, aucune donnée externe enregistrée en base. Sources et limites.