Intra-Rater, Inter-Rater, and Test–Retest Reliability of a Laser- and Inclinometer-Based Hip Joint Position Sense Test in Healthy Adults: A Two-Phase Study with Preliminary Reference Values

0Citations signalées — pas une note de qualité
8Institutions déclarées
3Pays d’affiliation déclarés

Résumé fourni par la source

Hip joint position sense (JPS), a key component of neuromuscular function arising from muscle spindle and periarticular mechanoreceptor input, remains underexplored, with no standardized and reliable clinical protocol available to assess hip proprioception. This study evaluated the intra- and inter-rater reliability of a laser- and inclinometer-based active hip JPS protocol and established preliminary references in healthy adults. A two-phase reliability study was conducted in accordance with GRRAS and COSMIN guidelines: 17 participants for reliability analyses and 57 for preliminary references. Six movement directions were assessed (flexion, extension, abduction, adduction, medial and lateral rotations). Reliability was quantified using intraclass correlation coefficients with their 95% confidence intervals, using two-way random-effects models with absolute agreement (ICC(3,1) for intra-rater and ICC(2,1) for inter-rater analyses), interpreted as poor (<0.50), moderate (0.50-0.70), or good (≥0.70). Absolute measurement error was reported as standard error of measurement (SEM%) and 95% minimal detectable change (MDC95%), normalized to target amplitudes to allow direct cross-direction comparison. Intra-rater reliability ranged from poor to moderate, with experienced raters reaching ICC = 0.64 (95% CI [0.39; 0.80]) for medial rotation. Inter-rater reliability improved across sessions, peaking for medial rotation (ICC = 0.78; 95% CI [0.50; 0.91]). Rotational movements yielded the lowest SEM% (3-6%), indicating high measurement precision despite trial-to-trial variability (MDC% 9-31%). Normative errors were largest in flexion (21.4 cm) and smallest in rotations (≈2.2-2.3°). Despite overall low-to-moderate reliability, the protocol achieved clinically acceptable measurement precision (SEM% < 10%) for rotational tasks, whereas the laser-based sagittal and frontal-plane components remained exploratory. The protocol provides preliminary reference values for hip JPS in healthy adults and requires further validation before clinical use.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Intra-Rater, Inter-Rater, and Test–Retest Reliability of a Laser- and Inclinometer-Based Hip Joint Position Sense Test in Healthy Adults: A Two-Phase Study with Preliminary Reference Values
Date Crossref
19/06/2026
Éditeur
MDPI AG
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude et ne compte pas comme une seconde source scientifique indépendante.

Institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Sujets associés

Muscle activation and electromyography studiesMusculoskeletal pain and rehabilitationHip disorders and treatments

BNTIC News n’est pas le producteur de ces données. Recherche à la demande dans Crossref et Europe PMC, sans clé ; OpenAlex reste optionnel. Aucun service payant requis, aucune réponse conservée. Sources et limites.