Aller au contenu principal
2026 article

Capillary UCH-L1 protein blood measurement is affected by sample hemolysis

0Citations signalées — pas une note de qualité
5Institutions déclarées
1Pays d’affiliation déclarés

Résumé fourni par la source

OBJECTIVES: Glial fibrillary acidic protein (GFAP) and ubiquitin C-terminal hydrolase L1 (UCH-L1) are internationally validated blood biomarkers for the management of mild traumatic brain injury (mTBI). Capillary blood sampling would facilitate point-of-care testing for dual GFAP/UCH-L1 determination, but it is more sensitive to pre-analytical variables such as hemolysis than venous blood measurements. The aim of this study was to compare capillary and venous assays and assess the impact of hemolysis on them. METHODS: Alinity system. Red blood cell hemolysate spiking experiments were performed on different analytical platforms able to measure GFAP/UCH-L1. A human albumin matrix experiment was also conducted to look for intra-erythrocytic presence of GFAP and UCHL-1. RESULTS: GFAP showed excellent correlation between capillary and venous samples (r=0.99; 95 % CI 0.98-1.0; p<0.001) with no potential clinically relevant impact on diagnostic thresholds. By contrast, UCH-L1 showed poor correlation (r=0.28; 95 % CI 0-0.57; p=0.058) and wide limits of agreement. Hemolysis caused marked overestimation of UCH-L1 using different analytical platforms, whereas GFAP remained stable. Spiking experiments confirmed that UCH-L1 overestimation was related to its presence in red blood cells. CONCLUSIONS: Capillary UCH-L1 is highly sensitive to hemolysis, limiting the reliability of its assay in capillary samples. By contrast, capillary GFAP assay displays robust analytical performance for mTBI management.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Capillary UCH-L1 protein blood measurement is affected by sample hemolysis
Date Crossref
22/06/2026
Éditeur
Walter de Gruyter GmbH
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude et ne compte pas comme une seconde source scientifique indépendante.

Institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Sujets associés

S100 Proteins and AnnexinsTraumatic Brain Injury and Neurovascular DisturbancesTraumatic Brain Injury Research

BNTIC News n’est pas le producteur de ces données. Recherche à la demande dans Crossref et Europe PMC, sans clé ; OpenAlex reste optionnel. Aucun service payant requis, aucune réponse conservée. Sources et limites.