Optical diagnostic design for measuring the radiation front with a mid-leg pumped divertor on DIII-D
Rattachement africain : us. Niveau de preuve : code pays fourni par la source.
Le résumé fourni par la source
The design of an optical diagnostic system to localize the radiation front in a mid-leg pumped divertor configuration on DIII-D is presented. Divertor detachment is a key mechanism for handling power exhaust in tokamaks, and mid-leg pumping offers a promising approach to radiatively dissipate power while maintaining acceptable core performance. To predict the location of the radiation front and design a spectroscopic diagnostic to measure its position, a database of SOLPS-ITER simulations across a range of input powers and gas puffing rates representative of DIII-D operation was employed. These simulations provide self-consistent plasma backgrounds for a Cherab-Raysect synthetic diagnostic framework, which incorporates detailed tokamak geometry and physically accurate ray-tracing. Synthetic simulations of optical sightlines and viewing cone geometry were used to calculate line-integrated emission from the plasma, particularly of the C III 465 nm line, to serve as a proxy for the Te ≈ 7-10$ eV temperature region associated with the onset and evolution of divertor detachment. Neutral deuterium emission is also evaluated for comparison. The synthetic diagnostic is used to assess the performance of existing DIII-D optical systems, including filterscopes and the Multichord Divertor Spectrometer, and to optimize line-of-sight placement within mechanical and installation constraints. The results provide quantitative guidance for diagnostic implementation on DIII-D and demonstrate the advantage of integrated synthetic diagnostics for divertor design studies and future advanced divertor concepts.
Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.
Le contrôle bibliographique ouvert
DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.
- Titre Crossref
- Optical diagnostic design for measuring the radiation front with a mid-leg pumped divertor on DIII-D
- Date Crossref
- 01/11/2026
- Éditeur
- Elsevier BV
- Type
- journal-article
Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.
Où se fait cette recherche
-
Oak Ridge National Laboratory pays non établi dans la noticeStructure de recherche
-
General Atomics (United States) pays non établi dans la noticeEntreprise
-
Lawrence Livermore National Laboratory pays non établi dans la noticeStructure de recherche
Oak Ridge National Laboratory, General Atomics (United States) et Lawrence Livermore National Laboratory.
Une affiliation ne permet pas de déduire la nationalité d’un auteur.