Aller au contenu principal
Accès ouvert déclaré 2026 article

Clinical efficacy and safety of paclitaxel-coated vs. limus-coated balloons in coronary interventions: a review of the literature

0Citations signalées — pas une note de qualité
4Institutions déclarées
2Pays d’affiliation déclarés

Résumé fourni par la source

The principle of complete vessel restoration in percutaneous coronary intervention (PCI) has highlighted the significance of drug-coated balloons (DCBs) as a crucial alternative to permanent metallic stents, which are associated with potential risks such as neoatherosclerosis and delayed stent thrombosis. Although paclitaxel-coated balloons (PCBs) are widely accepted as the preferred option for managing in-stent restenosis (ISR) due to their lipophilic and cytotoxic characteristics, sirolimus-coated balloons (SCBs) have emerged as a potentially less risky alternative, using a cytostatic mode of action. This review synthesizes clinical evidence from 10 randomized controlled trials (RCTs) and 7 meta-analyses published between 2020 and 2025. The analysis focuses on comparative safety and efficacy across major indications: in-stent restenosis (ISR), de novo small vessel disease (SVD), and bifurcation lesions. In-Stent Restenosis (ISR): Multiple trials (such as Scheller et al., 2022, BIO ASCEND ISR) demonstrated the non-inferiority of limus-based platforms compared to PCBs. For instance, late lumen loss (LLL) was nearly identical between groups (0.25 mm for the PCB group vs. 0.26 mm for the SCB group). However, the REFORM trial failed to show non-inferiority for a biolimus-coated balloon, highlighting that outcomes often reflect device-specific effects rather than a class effect. De Novo Small Vessel Disease: Outcomes in this category were more heterogeneous. In the TRANSFORM I trial, the MagicTouch SCB failed to meet non-inferiority for net lumen gain compared to the SeQuent Please Neo PCB. Conversely, other studies observed comparable LLL between the two platforms. Safety Profile: Across most indications, Major Adverse Cardiovascular Events (MACE) and Target Lesion Failure (TL F) rates were comparable between paclitaxel and sirolimus platforms at 12-month follow-up. PCBs demonstrated a higher frequency of "late lumen enlargement" compared to SCBs. Both paclitaxel and sirolimus-based DCBs are effective for treating in-stent restenosis. However, in de novo lesions, PCBs currently maintain a more consistent evidence base. Clinical performance appears heavily dependent on device-specific factors, such as coating technology and excipient formulation, rather than a general class effect. Extended follow-up data of 3-5 years are still required to fully evaluate long-term safety and the risk of very late thrombosis.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Clinical efficacy and safety of paclitaxel-coated vs. limus-coated balloons in coronary interventions: a review of the literature
Date Crossref
01/06/2026
Éditeur
Elsevier BV
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude et ne compte pas comme une seconde source scientifique indépendante.

Institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Sujets associés

Coronary Interventions and DiagnosticsCardiac and Coronary Surgery TechniquesAcute Myocardial Infarction Research

BNTIC News n’est pas le producteur de ces données. Recherche à la demande dans Crossref et Europe PMC, sans clé ; OpenAlex reste optionnel. Aucun service payant requis, aucune réponse conservée. Sources et limites.