Aller au contenu principal
Accès ouvert déclaré 2026 article

Leaflet Splitting to Prevent TAVR-Induced Coronary Obstruction in Stented vs Stentless Surgical Bioprosthetic Valves.

0Citations signalées, ce qui n’est pas une note de qualité
1Institutions déclarées
1Pays d’affiliation déclarés

Rattachement africain : at. Niveau de preuve : code pays fourni par la source.

Le résumé fourni par la source

Background Transcatheter electrosurgical leaflet splitting prevents coronary artery obstruction (CAO) following transcatheter aortic valve replacement (TAVR), particularly in valve-in-valve interventions. Morphologic and fluoroscopic differences between stented and stentless valves may affect outcomes, but comparative data are limited.Objectives The aim of this study was to compare procedural characteristics and outcomes of BASILICA (bioprosthetic or native aortic scallop intentional laceration to prevent iatrogenic CAO) and TAVR in stented vs stentless surgical bioprosthetic valves.Methods A total of 131 patients undergoing BASILICA and valve-in-valve TAVR from the multicenter EURO-BASILICA registry were included. Patients were stratified by valve type (stented vs stentless), and outcomes were described according to Valve Academic Research Consortium 3 recommendations.Results Overall, 115 patients (87.8%) had stented valves and 16 (12.2%) had stentless valves. Risk for CAO was comparable, but stentless valves had longer leaflets (17.0 vs 14.0 mm; P < 0.001). Procedures in stentless valves required more contrast medium (174.0 vs 91.0 mL; P < 0.001) and longer fluoroscopy (61.7 vs 41.0 min; P = 0.023) and showed a trend toward longer procedure time. Technical success was similar, but stentless valves were associated with a significantly higher rate of target leaflet-related CAO (44.4% vs 7.1%; P < 0.001), which was mainly partial and non-flow-limiting (33.3% vs 3.9%; P < 0.001). In-hospital complications and 30-day outcomes were similar. No late CAO or myocardial infarction occurred during 1-year follow-up.Conclusions BASILICA is technically feasible for both stented and stentless valves. However, stentless valves had a higher rate of partial CAO after BASILICA and TAVR and may therefore require additional or alternative coronary artery protection measures in selected patients.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Le contrôle bibliographique ouvert

La source scientifique ouverte est momentanément indisponible.

Les institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Les sujets associés

Cardiac Valve Diseases and TreatmentsCardiac and Coronary Surgery TechniquesCoronary Interventions and Diagnostics

BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.