Background Cardioneural ablation (CNA) targets ganglionated plexi to abolish vagal inputs causing bradycardia in refractory vasovagal syncope (VVS). Long term real-world data on procedural methodology, safety, and long-term outcomes remain limited. Methods We conducted a retrospective single-center study of 25 patients with refractory VVS undergoing CNA at a UK tertiary syncope center (2013-2023). Patients had recurrent syncope despite lifestyle modifications and pharmacotherapy, with documented bradycardia via implantable loop recorder or head-up tilt testing. Procedures involved electroanatomical mapping, high-frequency stimulation of ganglionated plexi, and extracardiac vagal stimulation (ECVS) via bilateral internal jugular catheters to confirm abolition of vagal responses. Primary outcomes included syncope recurrence and quality-of-life measures. Results Mean age was 32±12 years (56% female), with baseline syncope frequency of 19±21 episodes/year. All procedures were technically successful, with mean procedure time 194±44 minutes and 18.3±8.3 radiofrequency lesions delivered. Superior and inferior paraseptal ganglia were targeted in 84% and 92% of cases, respectively. ECVS abolished atrioventricular block in 91% and sinus arrest in 86%. At 12-month follow-up, syncope frequency decreased to 0.6±1.3 episodes/year (p<0.001), and to 0.0±0.2 at mean 34.4-month follow-up. Quality-of-life scores improved significantly (EQ-5D: 0.78→0.92, p<0.001; VAS: 59→83, p<0.001). Midodrine was discontinued in all patients. One patient required permanent pacemaker implantation for procedural sinus arrest. Syncope recurred in 24%; repeat ablation was required in 12%. Conclusions CNA demonstrates sustained efficacy and safety for refractory VVS with significant quality-of-life improvements in this real-world cohort.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Le contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
481 Real-world outcomes of cardioneural ablation for refractory vasovagal syncope: 10-year UK tertiary centre experience
Date Crossref
01/06/2026
Éditeur
BMJ Publishing Group Ltd and British Cardiovascular Society
Type
proceedings-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.

Les institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Les sujets associés

Cardiovascular Syncope and Autonomic DisordersHeart Rate Variability and Autonomic ControlPathogenesis and Treatment of Hiccups

BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.