Aller au contenu principal
Accès ouvert déclaré 2026 article

An automated quantitative report for multiple sclerosis using only 3D T2-fluid-attenuated inversion recovery MRI

0Citations signalées, ce qui n’est pas une note de qualité
23Institutions déclarées
8Pays d’affiliation déclarés

Rattachement africain : gb, de, es, nl, Éthiopie, it, no, at. Niveau de preuve : code pays fourni par la source.

Le résumé fourni par la source

PURPOSE: Automated tools quantifying multiple sclerosis (MS) imaging biomarkers often require non-routine MRI sequences and lack MS reference data. We developed an open-source quantitative report (QReport) that integrates validated 3D T2-FLAIR quantification methods with multi-centre MS and healthy reference models, and presents outputs in a structured graphical report to support contextualised interpretation of clinically relevant biomarkers. METHODS: 2516 cross-sectional 3D T2-FLAIR scans from people with MS (pwMS) and healthy controls (HC) were retrospectively collected from 14 centres within Magnetic Resonance Imaging in MS (MAGNIMS) and affiliated sites, as well as open-source datasets. Validated T2-FLAIR-based algorithms quantified total and regional lesion count (LC), lesion volume (LV), brain volume (BV), and brain age gap estimation (BrainAGE). Distributions in pwMS and HC were estimated using quantile regression. A QReport was designed to present biomarkers and reference models in graphical formats. Four neuroradiologists assessed agreement between QReport outputs and their visual assessment, and evaluated its usefulness, in 22 cases. RESULTS: We analysed scans from 1723 HC (age, mean ± SD: 54.5 ± 16.0; range: 18-75; F/M: 949/774) and 793 pwMS (age, mean ± SD: 43.0 ± 11.1; range: 18-75; F/M: 538/255) across 14 centres. The QReport presents single-subject measures contextualised against the 95th, 50th, and 5th percentile distributions in pwMS and HC, and includes BrainAGE. In 94% of evaluations, QReport outputs demonstrated Moderate-to-Complete agreement with visual assessment and were rated as useful in 82%. CONCLUSION: We developed an MS QReport requiring only 3D T2-FLAIR, integrating validated quantification algorithms and incorporating BrainAGE within a clinically interpretable framework.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Le contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
An automated quantitative report for multiple sclerosis using only 3D T2-fluid-attenuated inversion recovery MRI
Date Crossref
06/06/2026
Éditeur
Springer Science and Business Media LLC
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.

Les institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Les sujets associés

Multiple Sclerosis Research StudiesAdvanced MRI Techniques and ApplicationsAdvanced Neuroimaging Techniques and Applications

BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.