1859-P: Optimizing Outcomes with the Twiist Automated Insulin Delivery (AID) System: Real-World Insights on Correction Range and Max Basal Rate Settings

0Citations signalées, ce qui n’est pas une note de qualité
1Institutions déclarées
1Pays d’affiliation déclarés

Rattachement africain : us. Niveau de preuve : code pays fourni par la source.

Le résumé fourni par la source

Introduction and Objective: twiist is an AID system with an algorithm based on Tidepool Loop, which was developed by the open-source community and offers advanced algorithmic flexibility to support individualized therapy. Two important parameters include the Correction Range (CR), which can be set from 87-180 mg/dL, and max basal rate. In this real-world analysis, we evaluated the association between CR and max basal rate with glycemic outcomes. Methods: We calculated max basal ratio (MBR) as a normalized ratio of the most recent max basal rate to the highest programmed basal rate. Users were grouped by CR (<100 mg/dL, 100-140 mg/dL) based on the midpoint of the CR that is used ≥75% of the time and the MBR (<7.5, ≥7.5) most recently used. Glycemic metrics were compared across groups Results: Among 774 users, most (79%, n=610) used CR 100-140 mg/dL and MBR <7.5, while smaller subgroups used more aggressive targets. The highest TIR was observed in CR <100 mg/dL & MBR <7.5 (n=61, TIR 82.8%, time <54 mg/dL 0.6%). Users with CR 100-140 mg/dL & MBR <7.5 (n=610) achieved lower TIR (72.1%) but the lowest hypoglycemia (time <54 mg/dL 0.4%). Table 1. Conclusion: While most twiist users employed standard settings, those who adopted more aggressive settings achieved greater TIR and Time in Tight Range. twiist’s flexibility to allow a low correction range and optimized basal modulation supports personalization of glycemic control. Disclosure J. Mitri: Employee; Current; Sequel. V. Shah: Advisory Panel; Current; Abbott Diabetes, Dexcom, Inc. Advisory Panel; Ended; Medtronic. Advisory Panel; Current; Novo Nordisk, Eli Lilly and Company. Consultant; Current; Insulet Corporation, T1D Exchange. Advisory Panel; Current; Sanofi, Tandem Diabetes Care, Inc. Consultant; Ended; DreaMed Diabetes, Ltd. R. Lal: Consultant; Current; Abbott Diabetes, Adaptyx Biosciences. Consultant; Ended; Biolinq, Capillary Biomedical, Deep Valley Labs. Consultant; Current; Gluroo, Portal Diabetes, Tidepool. Advisory Panel; Ended; ProventionBio, Lilly, Sanofi, Rezolute. J. Jacoby: None. K. Snow: Employee; Current; Sequel Medtech.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Le contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
1859-P: Optimizing Outcomes with the Twiist Automated Insulin Delivery (AID) System: Real-World Insights on Correction Range and Max Basal Rate Settings
Date Crossref
05/06/2026
Éditeur
American Diabetes Association
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.

Les institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Les sujets associés

Diabetes Management and ResearchDiabetes Treatment and ManagementHyperglycemia and glycemic control in critically ill and hospitalized patients

BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.