Indocyanine Green Fluorescence for Intraoperative Tumor Identification During Resection of Pediatric and Adolescent Intra-Abdominal Malignancy: A Prospective Multi-Institutional Observational Study
Rattachement africain : us, ca. Niveau de preuve : code pays fourni par la source.
Le résumé fourni par la source
BACKGROUND: Real-time intraoperative discrimination of malignant tissue during pediatric solid tumor resection is limited, constraining margin optimization; the utility of indocyanine green (ICG) fluorescence in this population remains incompletely defined. STUDY DESIGN: Prospective, observational, multi-institutional study (2019-2023) of pediatric, adolescent, and young adult patients undergoing resection of intra-abdominal solid malignancies following preoperative ICG administration. The primary endpoint was diagnostic accuracy of ICG fluorescence for tumor-containing specimens; secondary endpoints included association with margin status and surgeon-perceived intraoperative benefit. RESULTS: Forty-three operations in 42 patients yielded 55 specimens, of which 47 (85%) were malignant. Diagnostic performance was highest in hepatic tumors (sensitivity 83%, positive predictive value 83%) and lower in adrenal and heterogeneous tumor types. ICG avidity was not associated with improved negative margin rates (86% vs 75%, p=0.47). Surgeons reported intraoperative benefit in 67% of cases, most commonly improved visualization. No ICG-related adverse events occurred. CONCLUSIONS: ICG fluorescence provides reliable tumor identification in hepatic malignancies but does not correlate with margin-negative resection, indicating limited utility for margin guidance. These data support tumor-specific application and further investigation of optimized fluorescence strategies, including dosing, timing, and alternative fluorophores, in pediatric oncologic surgery.
Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.
Le contrôle bibliographique ouvert
DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.
- Titre Crossref
- Indocyanine Green Fluorescence for Intraoperative Tumor Identification During Resection of Pediatric and Adolescent Intra-Abdominal Malignancy: A Prospective Multi-Institutional Observational Study
- Date Crossref
- 03/06/2026
- Éditeur
- Ovid Technologies (Wolters Kluwer Health)
- Type
- journal-article
Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.
Les institutions déclarées
Une affiliation ne permet pas de déduire la nationalité d’un auteur.